66:ENGINE-RUN
Starting and testing the jet engine without the remote control
Activate the test run with the Up key (ON) and press the SET key to switch to the operating status
display:
The throttle/thrust display now shows
-rel
(release) and waits for your clearance with the Down
key: The fully automatic starting prodecure is activated.
Operation:
You can stop the test run at any time with the SET key (like an emergency switch).
With the Up/Down keys, you can adjust the thrust between IDLE and 100 % (similar
to the R/C throttle).
CAUTION: Please keep in mind that a stationary test run of the jet engine can lead to
very high temperaures in the aircraft model (exhaust duct) due to the reduced airflow.
67:JETRONIC-OFF
Manual switching of the JETRONIC to energy saving mode (sleep mode)
Press the Up key to activate the sleep mode (YES) and turn off directly with the SET key.
Standard value: NO
The JETRONIC is automatically switched to sleep mode if the following is true for a period of at
least 4 minutes:
✗
No RC1 signal is present,
✗
cooling down is finished and
✗
no keys are pressed.
By switching the R/C transmitter on (RC1 signal), the JETRONIC is activated again. In sleep mode
the current consumption is 1,3mA only, which is about 1 month by an battery charge of 1000mAh.
37
Содержание B110neo
Страница 2: ...B110neo B170neo B220neo Instructions 6 0 2...
Страница 4: ...B110neo B170neo B220neo Instructions 6 0 4...
Страница 10: ...B110neo B170neo B220neo Instructions 6 0 10...
Страница 12: ...B110neo B170neo B220neo Instructions 6 0 12...
Страница 13: ...B110neo B170neo B220neo Instructions 6 0 Installation Plan 13...
Страница 14: ...B110neo B170neo B220neo Instructions 6 0 14...
Страница 24: ...B110neo B170neo B220neo Instructions 6 0 24...
Страница 38: ...B110neo B170neo B220neo Instructions 6 0 38...
Страница 42: ...B110neo B170neo B220neo Instructions 6 0 42...
Страница 43: ...B110neo B170neo B220neo Instructions 6 0 Notes 43...