B110neo – B170neo – B220neo – Instructions 6.0
2:STATISTICS – Display of Operating Statistics
20:RUNS-TOTAL
shows the total number of engine runs or engine starts so far.
Unit: #
21:START-ABORT
shows the total number of aborted engine starts.
Unit: #
22:RUNS-ABORT
shows the total number of aborted engine runs where PWR shows the number of power-failures.
Unit: # PWR:#
23:HOUR-METER
shows the total operating time of the jet engine resp. the fuel pump.
Unit: HH:MM'SS
24:JET-ENGINE
shows the thrust class, the identification, serial number and running time of the jet engine.
Unit: ID SERIAL LIFE
170neo18512 10.50
type
year+serial lifetime
The lifetime value indicates the total number of turbine revolutions in millions.
A
!
after the serial number means "stored value", for example with no engine connected.
25:FIRMWARE
shows the info string of the current firmware with the version number.
26:UPGRADE-CODE
shows the upgrade-codenumber of the connected jet engine.
The engines thrust-class can be upgraded by purchase and entering a activation code here.
27:RESET-ENGINE
entering a 'YES' resets the internal engine settings.
26
Содержание B110neo
Страница 2: ...B110neo B170neo B220neo Instructions 6 0 2...
Страница 4: ...B110neo B170neo B220neo Instructions 6 0 4...
Страница 10: ...B110neo B170neo B220neo Instructions 6 0 10...
Страница 12: ...B110neo B170neo B220neo Instructions 6 0 12...
Страница 13: ...B110neo B170neo B220neo Instructions 6 0 Installation Plan 13...
Страница 14: ...B110neo B170neo B220neo Instructions 6 0 14...
Страница 24: ...B110neo B170neo B220neo Instructions 6 0 24...
Страница 38: ...B110neo B170neo B220neo Instructions 6 0 38...
Страница 42: ...B110neo B170neo B220neo Instructions 6 0 42...
Страница 43: ...B110neo B170neo B220neo Instructions 6 0 Notes 43...