![Everglades 320 EX Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/everglades/320-ex/320-ex_owners-manual_2443857077.webp)
77
Electrical System
in the engine gauge cluster, activate the charger
and turn the engine battery switches on. Turn the
ignition key switch for each engine to the “ON”
position (DO NOT START THE ENGINES) and read
the voltage on the volt meter for each engine. If
the batteries are in good condition and charging
properly, the volt meters will indicate between 12
and 14.5 volts. If the reading is below 12 volts,
then the battery is not accepting a charge or the
charger is not working properly. Always turn the
ignition switches off immediately after the moni-
toring is complete when using the voltmeters in
the engine gauge cluster.
Outlets
Supplies 120 volt AC electrical current to the cabin
Ground Fault Interrupter (G.F.I.) outlets.
Notice:
All AC electrical outlets are provided with
ground fault interrupts to protect against
electric shock. These outlets should be test-
ed periodically to ensure proper operation by
pressing the test/reset buttons in the center
of the faceplate. G.F.I. outlets do not protect
against short circuits and overloads. This is
done by the Outlets breaker on the AC panel.
WARNING
GFI OUTLETS DO NOT PROVIDE 100% PROTECTION
FROM ELECTRIC SHOCK. EVEN THOUGH GROUND FAULT
INTERRUPTERS PROVIDE PROTECTION BY REDUCING
EXPOSURE TIME FROM LINE TO GROUND SHOCK HAZARDS,
IT IS STILL POSSIBLE TO RECEIVE AN ELECTRIC SHOCK FROM
DEFECTIVE APPLIANCES OR POWER TOOLS AND MISUSED
ELECTRICAL EQUIPMENT.
Cockpit Refrigerator
Supplies 120 volt electrical current directly to the
cockpit refrigerator.
Water Heater
Supplies electrical current directly to the hot water
heater circuit. A thermostat in the water heater
control panel automatically controls the water
temperature. Before operation, you must have
water in the water heater. (See the water heater
manual for details)
Battery Charger
GFI Outlet Test and Reset Buttons
Содержание 320 EX
Страница 1: ...OWNER S MANUAL 2013 320 EX 350 EX...
Страница 2: ...2 Revision 1 01 10 2013...
Страница 16: ...16 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 25: ...25 Operation...
Страница 54: ...54 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 60: ...60 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 130: ...130 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 145: ...145 SCHEMATICS Appendix A...
Страница 146: ...146 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 151: ...151 MAINTENANCE LOG Appendix C Hours Date Dealer Service Repairs...
Страница 152: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 153: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 154: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 155: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 156: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 157: ...157 Appendix D BOATING ACCIDENT REPORT...
Страница 158: ...158 Boating Accident Report...
Страница 159: ...159 Boating Accident Report...
Страница 160: ...160 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 162: ...162 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 169: ...CAUSE AND SOLUTION...
Страница 170: ...Everglades Boats 544 Air Park Road Edgewater Florida 32132 All Channels Lead to Everglades Boats...