![Everglades 320 EX Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/everglades/320-ex/320-ex_owners-manual_2443857073.webp)
73
Electrical System
Recommended procedure for making a
shore connection:
Turn the AC Shore Main breakers to the “OFF” posi
-
tion. If the dockside outlet includes a disconnect
switch, turn it to the “OFF” position also.
To avoid strain on the cable make sure it has more
slack than the mooring lines. Dress the cable so
it cannot be damaged by chafing between the
boat and the dock. Make sure the cable doesn’t
come in contact with the water and connect the
cable in the boat plug inlet and then the dockside
outlet, making sure the connection plugs include
a three-prong plug with a ground wire. Tighten
the lock rings on both the shore and the boat
connector plugs.
Turn the dockside disconnect switch or circuit
breaker to the ON position. Then turn the circuit
breaker at the boat inlet plug on and check for
proper polarity. If reversed polarity has been
achieved, the red reversed polarity indicator in the
cabin AC panel will light. If this should happen,
make sure the Shore Main breaker on the panel
is in the “OFF” position and turn the dock power
switch or breaker off. If the Shore Main light il-
luminates and the red Reversed Polarity light does
not illuminate when power is supplied to the panel
the polarity is correct and the AC main breaker
can be moved to the “ON” position.
Check the ELCI panel in the system compart-
ment for faults. The green “POWER” LED should
show steady illumination and the red “FAULT” LED
should remain off. The ELCI trips and opens the
main circuit when there is a ground fault condi-
tion. If the red LED is continuously illuminated
the ELCI has tripped due to a ground fault condi-
tion. Some faults are self-clearing. Try resetting
the ELCI once. If the green LED shows steady
illumination and the ElCI does not trip again, the
circuit is correct and activated.
If the reversed polarity light is lit or the ELCI con-
tinues to trip and the red “FAULT” LED is lit after
being reset there is a problem with the AC electri-
cal system and it is unsafe to use. Make sure the
Shore Main breaker on the panel is in the “OFF”
position and turn the dock power switch or breaker
off. Disconnect the shore power supply cord from
the boat and notify a qualified marine electrician
to check the wiring and correct the problem.
Shore Power Inlet Plug, Shore Water Connection
and Fresh Water Tank Fill Fitting
DANGER
REVERSED POLARITY AND GROUND FAULT CONDITIONS
WILL DAMAGE THE SYSTEM AND EXPOSE PASSENGERS
TO ELECTROCUTION HAZARDS THAT WILL CAUSE SEVERE
INJURY OR DEATH. THIS CONDITION COULD ALSO CAUSE
A FIRE IN THE ELECTRICAL SYSTEM. NEVER OPERATE THE
AC ELECTRICAL SYSTEM WITH REVERSED POLARITY OR A
GROUND FAULT CONDITION.
WARNING
ELECTRIC SHOCK CAN CAUSE SEVERE INJURY OR EVEN
DEATH. DO NOT ATTEMPT TO CORRECT THE WIRING
YOURSELF. ALWAYS HAVE A QUALIFIED ELECTRICIAN CHECK
WIRING.
KEEP CHILDREN AWAY FROM ANY ELECTRICAL CABLES OR
EQUIPMENT AND ALWAYS USE GROUNDED APPLIANCES ON
BOARD YOUR BOAT.
UNDETECTED FAULTS IN THE AC ELECTRICAL SYSTEM
COULD CAUSE THE WATER AROUND THE BOAT TO BECOME
ENERGIZED. THIS COULD CAUSE A SEVERE SHOCK OR EVEN
DEATH TO SOMEONE IN THE WATER NEAR THE BOAT. NEVER
SWIM OR ALLOW SWIMMING AROUND THE BOAT WHEN THE AC
SYSTEM IS ACTIVATED BY THE SHORE POWER CONNECTION
OR THE GENERATOR.
Содержание 320 EX
Страница 1: ...OWNER S MANUAL 2013 320 EX 350 EX...
Страница 2: ...2 Revision 1 01 10 2013...
Страница 16: ...16 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 25: ...25 Operation...
Страница 54: ...54 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 60: ...60 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 130: ...130 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 145: ...145 SCHEMATICS Appendix A...
Страница 146: ...146 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 151: ...151 MAINTENANCE LOG Appendix C Hours Date Dealer Service Repairs...
Страница 152: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 153: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 154: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 155: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 156: ...MAINTENANCE LOG Hours Date Dealer Service Repairs...
Страница 157: ...157 Appendix D BOATING ACCIDENT REPORT...
Страница 158: ...158 Boating Accident Report...
Страница 159: ...159 Boating Accident Report...
Страница 160: ...160 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 162: ...162 THIS PAGE WAS LEFT BLANK INTENTIONALLY...
Страница 169: ...CAUSE AND SOLUTION...
Страница 170: ...Everglades Boats 544 Air Park Road Edgewater Florida 32132 All Channels Lead to Everglades Boats...