![EverFocus NVR 8004X Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/everfocus/nvr-8004x/nvr-8004x_user-manual_2443444055.webp)
NVR8004X
48
4.3.3
Other
You can configure the event settings and enable the Buzzer or Email alert for notifications.
The event options include:
Fan Failure
,
Disk Temperature
,
Disk Failure
,
Disk Full
,
Disk Off
,
Power Loss
and
Network Loss
.
4.3.3.1 Disk Temperature
Figure 4-19
Log:
Check the box to record alarm events to log data.
Email Notify:
Check the box to send email notification when system / Hard Disk’s (HD)
temperature is over the “Temp. Warning Limit”. Email operation requires valid email
entered in the Email setup menu (see
4.5.2 Email
).
Network Alarm:
Check the box to send out a network alarm to a client PC. This feature
works with EverFocus’ CMS software. You will need to configure the Alarm Server for the
NVR to send network alarms to the client PC (see
4.5.5 Alarm Server
).
Stop Recording:
Check box to stop recording when System / HD’s temperature is over the
“Temp. Warning Limit”.
Temp. Warning Limit:
Sets the trigger temperature for System / HD Temperature event
actions. Choose between 45
°
C /113
°
F and 70
°
C /158
°
F.