Page 24
Appendix C Optional Remote Control
BD500 Broadcast Profanity Delay
©Eventide Inc. 1995-1999
doc release 10
Configuring Optional Rear Panel Inputs and Outputs
The remote control feature supports up to 7 inputs and 4 outputs which may be connected to switches and
relays. Using configuration mode, the inputs may be used to operate all of the front panel button functions
and a few other functions as well. The assignment of the input lines to various commands is handled by the
configuration mode. The remote outputs are also configurable to signal many different conditions in the BD500.
If the remote conotrol option is installed the configuration mode will have an additional level of configurable
items. This will be the
6RE
level. To access this level go into configuration mode as described in chapter 3
and move up the levels using the RAMP TO ZERO button until the
6RE
level is reached. Now use the WAIT
AND EXIT and WAIT FOR SAFE buttons to navigate across the level. You will have the option of configuring
the seven input signals and the four output signals.
Each configurable input may be configurated to actuate one of several commands in the BD500. Similarly
the outputs are configurable to be actuated when one of several conditions occurs in the BD500.
Note: U is represented by
U
, W is represented by
W
, and V is represented by
V
.
Input Signals
The commands the inputs may be configured to are:
•
OFF
Off
causes input signal to have no function (factory default)
•
BYP
Bypass
same as the BYPASS button
•
CNF
Configure
same as the CONFIGURE button
•
WFS
Wait For Safe
same as the WAIT FOR SAFE button
•
WAE
Wait And Exit
same as the WAIT AND EXIT button
•
REB
Rebuild
same as the REBUILD button (used in precision fixed delay as decrement)
•
RT0
Ramp To Zero
same as the RAMP TO ZERO button (used in precision fixed delay as
increment)
•
SNE
Sneeze
same as the SNEEZE button (used in precision fixed delay as digit select)
•
DU
Dump
same as the DUMP button
•
LIV
Live
cancel all commands and go to 0.00 delay
•
STA
Static
cancel all commands and hold at current delay
•
FUL
Full Delay
cancel all commands and go to full delay
•
MUT
Mute
momentary audio output mute.
•
SBI
Station Break Insert mutes the outputs while save the audio into the buffer. When the buffer
reaches 4 seconds this mode ends and the unit goes into ramp to zero mode.
•
RTB
Ramp To Bypass
•
D-R
Dump into Rebuild
dump and then force rebuild mode.
•
E-R
Wait and Exit/Rebuild Toggle between wait&exit and rebuild
•
0-R
Ramp to Zero/Rebuild
Toggle between ramp to zero and rebuild
Input Explainations
The Bypass, Configure, Wait For Safe, Wait And Exit, Rebuild, Ramp To Zero, Sneeze, and Dump selections
are identical in function to the front panel buttons. A closure on one of these inputs will duplicate the front
panel operations. Only if a button on the front panel is actually depressed will these commands be overrid-
den. These closures also perform the same operation in precisision fixed delay mode as the front panel buttons
of the same name.
There are additional functions available via these inputs that are not available on the front panel. These
are described below.
Input Commands not available via front panel
Static
This command cancels the current function. This puts the unit in a mode that is the
same as if the RAMP TO ZERO button were pressed while the unit was ramping to
zero. This command has no function in precision fixed delay mode.
Содержание BD500
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 16: ...Page 12 Chapter 2 Operation BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 22: ...Page 18 Chapter 3 Configuration BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 26: ...Page 22 Appendix B Basic Remote Control BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 50: ...Page 46 Appendix G Specifications BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...