
BD500 Broadcast Profanity Delay
Chapter 2 Operation
Page 9
©Eventide Inc. 1995-1999
doc release 10
After a few minutes, the delay will reach maximum and the REBUILD button's indicator will turn off. The
rebuild process is complete, but the delay remains in rebuild mode. This means that if SNEEZE or DUMP is
used, after the SNEEZE or DUMP button is released, the delay will automatically rebuild back to maximum.
Starting a Show Segment with WAIT FOR SAFE
This process is used to start a show rapidly. The guest or dial-in caller are enabled immediately after the
studio goes on-the-air.
Before beginning, the transmitter is not getting its source from the BD500.
• The operator needs to know, or to set, the configuration value of safe time (default is 4.00 seconds.)
• Safe time (or more) before the studio goes on-the-air the operator presses the WAIT FOR SAFE button.
• The host begins talking immediately.
When the DUMP button illuminates:
• The WAIT FOR SAFE process has completed.
• The SAFE relay output is enabled.
• The engineer or host fades the output of the BD500 into the transmitter. (see note below)
• The host may begin taking dial-in callers.
The BD500 drops into rebuild mode and slowly completes building up to maximum delay.
Note: During the 4-second period that wait for safe is running and the WAIT FOR SAFE button's indicator
is flashing, the microphone audio is passed directly to the BD500 outputs. It is usually undesirable to have
that audio pass over the air. Use a mixer or other control to disable that audio until the show is scheduled to
start.
Ending a Show Segment with RAMP TO ZERO
This process gradually reduces the delay and takes a variable amount of time up to a few minutes.
During the show, the BD500 would usually remain in rebuild mode at maximum delay. Whenever SNEEZE
or DUMP is used, the unit rebuilds back to maximum. To end the show, press RAMP TO ZERO. The delay
will reduce in several minutes to 0.00 while the RAMP TO ZERO button's indicator flashes. During ramp to
zero the DUMP and SNEEZE buttons will continue to be available, but an eye should be kept on how much
time is actually still available to be dumped or sneezed away. To stop the ramp to zero process, press the RAMP
TO ZERO button. The unit will go to static mode (delay not changing). The ramp to zero process may be re-
sumed, or another function may be started.
Once the ramp to zero process is complete, the unit will operate at 0 delay.
Ending a Show Segment with WAIT AND EXIT
This process rapidly reduces the delay and takes 8 seconds or less.
At the end of the show, after the last word is spoken, press the WAIT AND EXIT button. All of the audio
delayed in the BD500 is output until the delay reaches 0.00. The WAIT AND EXIT button's indicator flashes
until the process is complete. Microphone audio is ignored by the BD500 during this process. When the delay
reaches 0.00, the unit goes into live mode in which input audio is passed directly through the delay.
Содержание BD500
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 16: ...Page 12 Chapter 2 Operation BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 22: ...Page 18 Chapter 3 Configuration BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 26: ...Page 22 Appendix B Basic Remote Control BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 50: ...Page 46 Appendix G Specifications BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...