Appendix C Optional Remote Control/Signalling
The Remote connector allows configurable inputs and outputs which may be assigned to control and moni-
tor front panel functions. This connector is optional. If this option is installed, there will be configuration
items available on configuration level
6RE
as described on the following pages. Also see Appendix A.
Remote Connector
This is a 15-pin female DB15 connector which allows 7 inputs to the BD500 and 4 outputs. All front panel
buttons are available for external control. In addition, outputs are provided on this connector to drive relays
which may be used for indicator lights and to enable audio signals.
pin 15
pin 8
pin 1
pin 9
Outputs
The four outputs are open collector drivers. Each can sink 200mA, all outputs driven. Each of the four out-
puts may be configured to reflect the operating mode of the unit (discussed later in this appendix).
Inputs
The seven inputs are used to trigger front panel switch functions and may be easily wired to remote switches.
pin 1
field contact supply output, 100mA max at a nominal voltage of 11.3v (see note) (pin 9 = ground)
pin 2
remote input 1
pin 3
remote input 3
pin 4
remote input 5
pin 5
remote input 7
pin 6
remote output 2
pin 7
remote output 4
pin 8
reference supply input for open collector output drivers, max 25v @ 1.6amps (pin 15 = ground)
pin 9
common ground for inputs
pin 10 remote input 2
pin 11 remote input 4
pin 12 remote input 6
pin 13 remote output 1
pin 14 remote output 3
pin 15 common ground for open collector driver outputs (pin 8 = voltage)
Notes:
• The field contact supply output is a BD500 supplied voltage to be used to trigger the BD500's remote in-
puts. This would be used for one side of a dry contact (switch or relay), the other side of which would go to
one of the BD500's remote inputs. This supply could also be used as the pull-up voltage for low current
relays.
• The reference supply input must equal the pull-up voltage for the open collector outputs. An inactive re-
mote output must be externally pulled up to this supply voltage. An active remote output is pulled to ground
by the BD500. The reference supply input is used for the internal clamp diodes.
• Remote inputs will be off if set to ground or floating (reference to pin 9), and on if a voltage greater than 4.5
volts is present. The input impedance is 3Kohms so the source must supply about 1mA at 4.5 volts DC or
more in order to signal an ON. The maximum input voltage is 25volts.
Optional Rear Panel
Remote Control Connector
Female DB15
Содержание BD500
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 16: ...Page 12 Chapter 2 Operation BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 22: ...Page 18 Chapter 3 Configuration BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 26: ...Page 22 Appendix B Basic Remote Control BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...
Страница 50: ...Page 46 Appendix G Specifications BD500 Broadcast Profanity Delay Eventide Inc 1995 1999 doc release 10 ...