7
MAIN CHARACTERISTICS
EXTERNAL UNIT TECHNICAL DATA
Notes
(ISO)
: data according to standard ISO 255-3
(EN)
: data according to standard EN 16147:2011
(SOL):
in solar version only
(1)
: heating cycle: Ambient temperature = 15°C B.S. / 12°C B.U. • Water initial temperature = 10°C
(2)
: standby: Ambient temperature = 15°C B.S. / 12°C B.U.
(3)
: Temperature limit in use 40°C • Inlet water temperature 10°C
(4)
: Check: water temp. 50°C, water flow rate 600l/h
MODEL
200 / 200 sol 300 / 300 sol
UM
Heat pump
Power supply
230-1-50
V-f-Hz
Heat output
(ISO)
1800
W
Power input
(ISO)
460
W
COP
3,91
W/W
Absorbed current
(ISO)
2,00
A
Heating time
(EN) (1)
5:20
9:00
h:min
Heating energy
(EN) (1)
2,40
3,98
kWh
Consumption in standby
(EN) (2)
35
40
W
Class of use
(EN)
L
L
type
Power consumption during
cycle of use
WEL-TC
(EN)
4,40
4,46
kWh
COP DHW
2,65
2,61
W/W
Reference temperature
55
55
°C
Max. quantity of water usable
(EN) (3)
0,254
0,381
m
3
Heating
element
Heat output
1500
W
Power input
1500
W
Absorbed current
6,5
A
Heat pump
+ heating
element
Power input
1960
W
Absorbed current
8,5
A
Max. power input
2050
W
Max. absorbed current
8,9
A
Storage tank
Volume
200
300
L
Max. operating pressure
10
Bar
Type
Stainless steel
-
Air
ducting
(SOL)
Fan
centrifugal
-
Max. \ min. air flow
350 \ 150
m³/h
Diameter
150
mm
Max. length
10
m
Solar coil
Type
Stainless steel
-
Solar coil diameter \ length
22\10
22\20
mm/m
Total area
1,0
2,0
m²
Max. operating pressure
10
Bar
Pressure drop
(4)
20
40
Noise levels
45
dB(A)
Dimensions
Unit diameter \ height
560\1705
640\1800
mm
Packing width \ height / depth
630x630x1740 740x740x1840 mm
Weight
Net
82
94
kg
Gross
98
114
kg