14
MODEL
200 Sol
250 Sol
300 Sol
U .M
Solar coil
Material
Stainless steel
Type
Coil diameter\length
22\10
22\15
22\20
mm/m
Coil area
1 .0
1 .5
2 .0
m²
Max . operating pressure
10
Bar
Connections
IN
G 3/4
"
OUT
G 3/4
"
Max . connectable area
Flat collectors
3 .0
5 .0
6 .0
m²
With vacuum pipes
2 .0
3 .0
4 .0
m²
CONNECTION TO SOLAR CIRCUIT (SOL VERSION)
SOL range units are designed for the production of domestic hot
water in conjunction with a solar system . The incorporated solar heat
exchanger enables the connection of solar collectors as given in the
table below. The unit's electronic regulation can control the fundamental
elements of the solar system .
Connect the solar circuit inlet at the place on the tank indicated
[SOLAR WATER INLET] and the return to the solar panel at the place
indicated [SOLAR WATER OUTLET]
The diagram opposite shows the recommended connection
A= Solar collector
B=solar circuit pump (managed by unit)
C=excess heat dissipating valve (managed by unit)
D=expansion tank
E=safety valve
F=shutoff valves
G=one-way valves
H=collector temperature sensor (supplied with unit)
IN=Coil inlet
OUT=Coil outlet
Incorporated solar coil characteristics:
WATER CONNECTIONS
F
Fig .1