E-Drive sur CF80 en Anglais
UCF-000R001-GB
F.M:08/14
p: 24/41
This option is interesting when sugary and salty products are alternately baked in the same oven with then possible strong residual smells inside the baking chamber
.
The function is used to absord the baking smells stored inside the oven in order to avoid the mixture of the different smells
(
Warning ! this function has no effect on smells dispersed
in the room
).
To obtain optimum results it is highly recommended to treat the water upstream (water softener) to avoid any deposit of limestone in the baking chamber and the formation of scale
in the whole system
.
The water solenoid valve is set to function at a working pressure around
3
bars
:
This setting must in no case be modified.
Since the real internal temperature of the oven must imperatively be at least 160°C to allow the cycle starting, when it is not the case, the regulator will automatically manage the temperature adjustment
as follows :
When the temperature is lower than setpoint, it will increase the temperature.
If the temperature inside the oven is equal to setpoint temperature, the cycle starts for 20mn
When the temperature is higher than setpoint, the cycle begins, the exhaust vent opens and stays open until the set temperature is reached
The duration of a cycle of odor absorption is 20 mn, with steam injection for 6 seconds every 2 mn
.
DO NOT OPEN the door during the cycle. BURNING RISKS.
When the cycle is finished, the door has to be open progressively to avoid burning risks by steam.
The best to do when the oven is hood equipped, is to set the door ajar and start the hood for few seconds in order to evacuate a maximum of steam.
SMELLS ABSORBER
Oven equipped with «Steam» option
Press simultaneously the
keys
(OUT OF BAKING)
Activation
The «Smells absorber» function
is activated
The buzzer rings
discontinuously during
30 seconds
The exhaust vent opens
automatically before the end of the
cycle according to the programmed
delay (Factory setting 1 mn - Look
at the paragraph «User menu» -
Programming instructions)
To exit from the
«Smells absorption»
mode while keeping the
control board on, press
the key
before
the end of the 30
seconds of buzzer
ringing.