E-Drive sur CF80 en Anglais
UCF-000R001-GB
F.M:08/14
p: 35/41
Measures allowing to solve a punctual malfunction
BAKING
General baking
irregularities
Check that all the baking settings are right (refer to the utilisation and baking advices).
Check that a supply fault (electric or other) hasn’t occured during baking.
Check the right rotation direction of the turbines. They must turn clockwise.
Check the good working of the regulator and the temperature sensor(s).
Check that the fermentation has occured normaly.
Check the tightness of the door (check the seal condition; if necessary replace it).
If it not tight, you can slightly open the exhaust vent until the renewal of the gasket.
Irregularity of baking
on several levels
Check the tightness of the door.
Check that the heating power is normal.
Check that the growth (fermentation) has been homogeneous on all the levels.
No function works.
Check that the control panel has been switched-on.
The oven refuses to
start its baking.
Check that the heating has been activated.
Check the safety thermostat. If the interruptions repeat, call a professional and approved repair
specialist.
Steam supply faulty
(if option).
Does the water supply well provided and with a sufficient outflow ?
Does the solenoid valve function normally ?
The water pressure must comply with the
minimum 3 bars necessary and the maximum
5 bars
.
On networks up to 5 bars, it is necessary to schedule a pressure regulator calibrated on 5 bars.
To change the quantity of steam, increase/decrease the steam duration with the regulator.
If the flow remain insufficient, contact the technical department.
OVEN
No function works.
Check that the electric supply is correct (power, isolator, connections, emergency stop button
pulled).
The oven refuses to
start its baking.
Check that the heating has been activated
.
Check that door closes correctly and that safety contact well operates.
Check the safety thermostat. If the interruptions repeat, call a professional and approved repair
specialist.
For a gas or fuel oven
Check the chimney safety thermostat. If the interruptions repeat, call a professional and
approved repair specialist.
Steam supply faulty
(if option).
Does the water supply well provided and with a sufficient outflow ?
Does the solenoid valve function normally ?
The water pressure must comply with the
minimum 3 bars necessary and the maximum
5 bars
. On networks up to 5 bars, it is necessary to schedule a pressure regulator calibrated on
5 bars.
To change the quantity of steam, increase/decrease the steam duration with the regulator. If the
flow remain insufficient, contact the technical department
PROBLEM SOLVING