To remove the beat flame top, take it with one hand in 
the middle, pull in a linear way down once you see all 
the spin box, rotate to remove it from the combustion 
chamber of the stove. Take the vacuum cleaner and 
clean the inside.  
 
 
 
 
 
 
 
 
 

 
 
At the bottom of the combustion chamber behind the 
support of the brazier there is another bulkhead to 
remove, grab her by the edge and pull up. 
 
 

 
 
 
 
 
Removed this piece, the two rear bulkheads are released, 
to remove them, simply take them off. Even at this stage 
take the vacuum cleaner to clean the entire inner part of 
the stove, if present of the residue pasted, carry a brush 
to remove it from all surfaces. 
 
 
 
 
 
 
 
 

 
When all surfaces are clean, remove the ash collection 
drawer and thoroughly clean even the latter. 
 
 
 
 
 
 

Содержание PASUBIO

Страница 1: ...Use and maintenance manual for pellet stove...

Страница 2: ...working of the stove and safety All the operations not provided for in the manual and not authorized by a technician recommended by the company must be considered dangerous Otherwise the ZF company d...

Страница 3: ...or criminal liability Before performing any operation the user must have read and understood all the contents of this manual Use and Maintenance Tampering and misuse of the stove can be dangerous for...

Страница 4: ...62233 EN 14785 The installation and use of the stove must be met in all the local and national laws and all European standards 5 Warranty Warranty conditions ZF Ltd located in Dino Fochesato Street n...

Страница 5: ...lid in the following cases The above warranty terms have not been observed The installation is not carried out in full obedience of the laws in force and the instructions contained in the provided man...

Страница 6: ...ubject to wear and tear are excluded from the warranty Gaskets Ceramic tempered glass Linings and grills Varnished details Chromate gilded Satin Majolica Handles Power lines Vermiculite Refractory mat...

Страница 7: ...iance with safety regulations Installation by unqualified and untrained personnel Installation not in accordance with the regulations in force in the country Use of non original spare parts Exceptiona...

Страница 8: ...t where the stove is placed It is not compulsory to connect the air pipe of the stove directly outside see figure but it is necessary to guarantee at least 50m h of air Grill 800cm The electrical syst...

Страница 9: ...h hermetically sealed gaskets It s important that the curvature of 90 provides for a T junction with inspection we advise you to use a curve of 45 Using nets or filters at the extremity of the flue or...

Страница 10: ...the base can also be applied inside the house preferably external If there is a fireplace it must have a preferably circular internal section the square or rectangular sections must have rounded corn...

Страница 11: ...products is assured windproof chimney pot The chimney pot must be positioned so as to ensure adequate dispersion and dilution of the combustion products and however outside the reflux area This area h...

Страница 12: ...d consequently in the opposite situation increases the depression decreasing the draught To overcome these drawbacks the installer must act directly on the stove modifying the parameter to adjust the...

Страница 13: ...ed power 104 6 C Flue gas temperature at reduced power 68 4 C Carbon dioxide at rated power 6 89 Carbon dioxide at reduced power 4 95 CO at 13 O2 at rated power 140 8 mg m CO at 13 O2 at reduced power...

Страница 14: ...e to the stove or to the room of installation In case of problems the ZF company disclaims any liability both civil and criminal First steps Check that there are no objects on the stove manual include...

Страница 15: ...the next submenu level PROGRAMMING It sets the selected menu and passes to the next entry 4 ON OFF WORK Pressed for 2 seconds it turns on and off the stove PROGRAMMING It passes to the next level of t...

Страница 16: ...OF OPERATION Premise The installer must make the first start by taking precautions and must ensure that the safety devices are working properly Vacuum gauge hopper temperature protection etc Any anoma...

Страница 17: ...1 minute the uploading phase begins the display scrolls the message LOAD PELLET In a first step the auger provides to load the pellets in the brazier for a time given by the parameter PR40 auger LED...

Страница 18: ...tained in PR13 and maintained it for at least a time PR02 the stove goes into working mode which is the normal operating The display will show the word WORK The power is set by holding down the P5 and...

Страница 19: ...Thus acting on the buttons P1 increase and P2 decrease it is possible to change the value After about 5 seconds the value is stored and the display returns to the normal mode or press P3 to exit Figu...

Страница 20: ...this state the stove has turned off the auger auger LED off the heat exchanger switches off when it reaches the threshold given by the parameter PR15 and the LED ON OFF flashes Figure 10a Figure 10a...

Страница 21: ...threshold given by the parameter PR10 the stove shuts off displaying the message OFF Figure 11a Figure 11a 11 THE MENU You can enter the menu by pressing the P3 button The menu is subdivided into diff...

Страница 22: ...sday Prg 2 on off 15 Wednesday Prg 2 on off 16 Thursday Prg 2 on off 17 Friday Prg 2 on off 18 Saturday Prg 2 on off 19 Sunday Prg 2 on off 20 start Prg 3 OFF 0 23 50 21 stop Prg 3 OFF 0 23 50 22 Mond...

Страница 23: ...info 04 Fumes state info 05 Fumes extraction revolutions state info Level 1 Level 2 Value M8 technician settings 01 access key set Level 1 Level 2 Value M9 exit 01 exit set 11 2 Menu M1 SET CLOCK Set...

Страница 24: ...2c day figure 12d month figure 12e and year figure 12f by pressing the P1 button increment and P2 button decrement and confirming by pressing the P3 button Figure 12b Figure 12c Figure 12d Figure 12e...

Страница 25: ...3a You can set two sections of functioning the first one with START1 Day and STOP1 Day and the second one with START2 Day and STOP2 Day delimitated by the times set according to the following table wh...

Страница 26: ...2 3 05 TUESDAY PRG 1 on off M2 3 06 WEDNESDAY PRG 1 on off M2 3 07 THURSDAY PRG 1 on off M2 3 08 FRIDAY PRG 1 on off M2 3 09 SATURDAY PRG 1 on off M2 3 10 SUNDAY PRG 1 on off PROGRAM 2 Menu level Sele...

Страница 27: ...ctioning of the stove for Sunday by setting Start2 weekend and Stop2 weekend WEEKEND PROGRAM Menu level Selection Meaning Possible values M2 4 01 WEEKEND TIME Enable weekend time ON OFF M2 4 02 STAR 1...

Страница 28: ...e first ignition of the stove figura 17 when the pellet tank is empty After having selected the menu M6 the message P1 to load will pass on the display figure 17a Then press P1 increment The fumes fan...

Страница 29: ...ed Meaning 3 1 Auger pellet load state 52 Time out Toff Thermostat state 106 Fumes temperature 1490 Fumes extraction speed Figure 18 11 9 Menu M8 Technician settings This menu entry is for the technic...

Страница 30: ...nitiated for safety During the alarm phase the alarms LED will always be lit Alarm LED lit and when enabled the buzzer will sound intermittently If you fail to reset the alarm the stove will shut down...

Страница 31: ...s expulsion is not detected by the board In this case reset the alarm by pressing the On Off button and contact an authorized service center Figure 23 12 5 Misfire Alarm It occurs when the ignition ph...

Страница 32: ...p press the button put the cap back restart the stove and check if the environment fan is working correctly If the alarm persists call the Authorized Service Provider Figure 27 12 8 Alarm absence depr...

Страница 33: ...an authorized service The flame did not send the fumes on right temperature within the prescribed time The pellet is finished refill the tank switch the stove on if the problem persists call the autho...

Страница 34: ...hould be made when the ash reaches the edge of the same drawer it is strictly forbidden to light the stove if the ash goes beyond it Every day when you clean the brazier also check if the drawer is em...

Страница 35: ...he inner walls of the stove with a brush Remove the brazier to proceed with the removal of interior walls Remove the internal bulkhead taking it by the two lower edges if this operation proves to be d...

Страница 36: ...mber behind the support of the brazier there is another bulkhead to remove grab her by the edge and pull up Removed this piece the two rear bulkheads are released to remove them simply take them off E...

Страница 37: ...eaning and physical state Do not reassemble broken or damaged parts may cause undesired operation of the stove Summary scheme of the cleaning and maintenance of the stove Daily Every 2 days Once every...

Страница 38: ...r criminal arising from the use of non original spare parts also informs that the use of these voids the warranty on the stove You will find the complete list of spare parts and related code to commun...

Страница 39: ...iore 1 35 R2600424 Ferma vetro laterale sx 1 36 R2600425 Tappo inferiore 1 37 R2600427 Staffa supporto serbatoio coclea 1 38 R2600428 Staffa supp motore coclea 1 39 R2600430 Braciere 6 9 kW EA 1 40 R2...

Страница 40: ...Hereinafter the diagram for the connection between the different electric parts and the motherboard of the stove is represented TSP safety thermostat vain pellets 15 Wiring diagram...

Страница 41: ...n The adjustment of the channeling can happen in two ways depending on the type of stove you have Manual Adjustment Automatic Adjustment Automatic Adjustment The adjustment of the air flow in this cas...

Страница 42: ...Below is an example of installation of ducted heater in a home environment...

Страница 43: ...17 Notes...

Страница 44: ...Notes...

Страница 45: ...xed municipal waste but it must be assigned to specialized collection structures as prescribed by local regulations or by the dealer The importer and the dealer are responsible for collection and disp...

Отзывы: