In the event that a malfunction occurs, the board intervenes and signals the irregularities, lighting
the LED Alarm (Alarm LED lit) and producing acoustic signals.
There are the following alarms:
Alarm origin
Display view
Energetic Black-out
AL 1 BLAC-OUT
Flue gas temperature sensor
AL 2 PROBE EXHAUST
Fumes overheating
AL 3 HOT EXHAUST
Encoder fumes failure
AL 4 FAN FAILURE
Misfire
AL 5 NO LIGHTIN-
Pellet absence
AL 6 NO PELLET
Overheating thermal safety
AL 7 SAFETY THERMAL
No depression
AL 8 FAILURE DEPRESS
Each alarm condition causes the immediate shutdown of the stove
The alarm state is reached after the time PR11,
EXCEPT THE ALARM OF BLAC-OUT,
and can be
reset by pressing and holding the button P4. Whenever an alarm is reset, a shutdown phase of the
stove is initiated for safety. During the alarm phase the alarms LED will always be lit (Alarm LED lit)
and when enabled the buzzer will sound intermittently. If you fail to reset the alarm, the stove will
shut down anyway, always displaying the alarm message.
12.1
Energetic Black out
During the working status of the stove, electricity may be missing. Upon restart, if the period of the
outage is less than the parameter PR48, the stove restarts on
WORK
mode, otherwise the alarm is
activated. The display scrolls the message "
Al 1 BLAC-OUT
" (
Figure 20
) and the stove goes off.
Figure 20
12.2 Fumes temperature sensor Alarm
It occurs in the case where the flue probe proves faulty. The stove goes into alarm, the alarms LED
lights up (Alarm LED lit). The Stove will show, "
Al 2 PROBE EXHAUST
" on the display (
Figure 21
) and
will go into shutdown. In
this case, reset the alarm by
pressing the On / Off button
and contact your authorized
service center.
Figure 21
12 ALARMS
Al1
BLAC
OUT
Al2
PROBE
EXHAUST