12.3 Fumes temperature Alarm
It occurs in the case where the flue probe detects a temperature higher than a set value fixed and
not changeable via parameter. The display shows the message "
Al 3 HOT EXHAUST
" as (
Figure 22
)
and the stove goes off.
Electrically disconnect the
stove
and
call
your
authorized service center.
Figure 22
12.4 Encoder smoke Alarm faulty
It happens in case there is a fault in the fumes fan. The stove goes into alarm state and the
inscription "
Al 4 FAN FAILURE
" (
Figure 23
) will scroll across the display. It occurs in the case in which
the fume extractor is faulty or in the case where the fan speed of the fumes expulsion is not detected
by the board. In this case,
reset the alarm by pressing
the On / Off button and
contact
an
authorized
service center.
Figure 23
12.5 Misfire Alarm
It occurs when the ignition phase fails. That is what happens if the time given by the parameter PR01
passes without the fumes temperature not exceeding the parameter PR13. The display will scroll the
inscription
"
Al 5 NO LIGHTIN- “
and
the stove goes into alarm
(
figure
24
).
Wait
for
completion of the cooling
cycle, clean the brazier and
proceed with a new ignition.
Figure 24
12.6 Pellets absence Alarm
It occurs when, in working phase, the flue gas temperature falls below the parameter PR13. The
display will scroll the
inscription"
Al 6 NO PELLET
"
and the stove goes into
alarm state (
Figure 25
).
Figure 25
Al3
HOT
EXHAUST
Al4
FAN
FAILURE
Al6
NO
PELLET
Al5
NO
LIGHTIN-