Manual EKS Ethernet TCP/IP
2547185-01-10/22
Subject to technical modifications
Page 19/38
4.7.2 DIP switch S2
DNS
name
LSB
S2.1
S2.2
S2.3
S2.4
S2.5
S2.6
S2.7
MSB
S2.8
S2.9*
S2.10*
EKS000
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EKS001
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EKS002
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
EKS003
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
…
…
…
…
…
…
…
…
…
…
…
EKS254
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
EKS255
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
* Only if modular interface adapter fitted. Internal function. Retain default setting.
Information!
Using the DIP switch S2, it is possible to set an EKS name that is used for addressing the device in the
network in conjunction with a DHCP server. This name consists of the fixed code EKS plus a
configurable number between 001 and 255 that can be used in all system environments with DHCP
support. The station name for a specific read/write station would then be EKS027, for example.
The DIP switch S2 is relevant specifically in conjunction with the Siemens SINUMERIK DHCP address
assignment routine (see chapter 6.1.1.3 Operation in the Siemens system network).
In this way it is possible to set the identical address by copying the DIP switch settings if a device is
replaced.
4.7.3 DIP switch S3
Function
S3.1
S3.2
S3.3
S3.4
Fixed IP address
OFF
OFF
OFF
Default IP address 192.168.1.1
OFF
ON
OFF
Obtain IP address from DHCP server
OFF
OFF
ON
Obtain IP address from a SINUMERIK control system
OFF
ON
ON
Internal function, leave switch OFF
OFF
Permit configuration via the web interface
OFF
OFF
OFF
OFF
(Factory setting: all in OFF position)
= any switch position
Information!
The use of the DIP switches to assign the IP address is described in the following in chapter 6.1.1.
To prevent unauthorized changes to the network, it is sensible to deactivate the web interface after use.
For this purpose switch S3.1 is set to ON.