Manual EKS Ethernet TCP/IP
Page 18/38
Subject to technical modifications
2547185-01-10/22
4.7 DIP switch settings
The device has three DIP switches (S1, S2, S3).
Compact device
DIP switch
Function
S1
(4-fold)
S1.1 … S1.4; write and read settings
S2
(8-fold)
S2.1 … S2.8; setting of a fixed DNS name (required only for special applications)
S3
(4-fold)
S3.1 … S3.4; settings for network connection and service
Modular device
DIP switch
Function
S1
(4-fold)
S1.1 … S1.4; write and read settings
S2
(10-fold)
S2.1 … S2.10; setting of a fixed DNS name (required only for special applications)
S3
(4-fold)
S3.1 … S3.4; settings for network connection and service
Information!
The settings are adopted only when the power supply is switched on.
4.7.1 DIP switch S1
DIP
switch Function
Factory setting
S1.1
ON = write protection for Electronic-Key read/write
OFF
S1.2
No function
OFF
S1.3
No function
OFF
S1.4
No function
OFF
Information!
It is
imperative
that all DIP switches without a function (S1.2, S1.3 and S1.4) are set to
OFF
! In this
way problems with any functions added in the future will be avoided.