Manual EKS Ethernet TCP/IP
Page 14/38
Subject to technical modifications
2547185-01-10/22
4.5 Technical data for modular version
Attention!
All the electrical connections must either be isolated from the mains supply by a safety transformer
according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
isolation measures.
General parameters
Value
Unit
min.
typ.
max.
General parameters of Electronic-Key adapter Front Hook Modular FHM
Housing
Plastic (PVDF GF20, gray)
Degree of protection
IP65/IP67/IP69K in installed state
Ambient temperature
-20
+70 / +100*
°C
Mounting bore
∅
22.5
mm
Connection
Connection cable permanently connected to Electronic-Key
adapter or with plug connector in the cable, with flying lead
Connecting cable length
2, 5, 10, 15
m
Connecting cable cross-section
4 x 0.25 screened
mm²
Connecting cable outer sheath
PVC
General parameters of modular interface adapter
Housing
Plastic (PA 6.6, gray)
Ambient temperature at U
B
= DC 24 V
0
+55
°C
Mounting
35-mm mounting rail acc. to DIN EN 60715 TH35
Number of connectible Electronic-Key
adapters
1
Connection for power supply and Electronic-
Key adapter
Plug-in connection terminals, 4-pin and 5-pin,
with screw terminal (tightening torque 0.22 Nm)
or spring terminal, conductor cross-section 0.2 ... 1.5 mm²
Cable length to Electronic-Key adapter
2
15
m
Operating voltage U
B
(regulated, residual ripple < 5 %)
20
24
28
DC V
Current consumption I
B
150
mA
Interface, data transfer
Interface to the control system
Industrial Ethernet (IEEE 802.3)
Transfer protocol
TCP/IP
Data transfer rate (full duplex)
10/100
Mbit/s
Connection for Ethernet interface
1 x RJ45 socket
Data line
2 x 2 twisted-pair copper cables, screened; min. category 5
Cable length
100
m
LED indicator read head
Green (STATE): "Ready" (in operation)
Yellow (ACTIVE): "Electronic-Key active" **
Red (DIA): "Error"
LED indicator Ethernet TCP/IP
Green (ON): "Active"
Red (CF): "Connection error"
Version
FSA
(For Safety Applications) – parameters for floating semiconductor switching contact LA
Switching contact connection
Plug-in connection terminal, 5-pin,
with screw terminal (tightening torque 0.22 Nm)
or spring terminal, conductor cross-section 0.2 ... 1.5 mm²
Power supply U for load (LA)
24
30
V
Switching current (with overload protection)
1
10
50
mA
Output voltage U
A
(LA) in switched state
U x 0.9
U
V
Resistance in switched state
35
ohms
Max. capacitive load
1
µF
Utilization category acc. to AC-12
EN IEC 60947-5-2 AC-15
DC-12
DC-13
50 mA / 24 V
Reliability values acc. to EN ISO 13849-1 (
FSA
version only)
Category (with downstream safe evaluation)
3
MTTF
D
Evaluation of data channel and one
switching contact LA
416
years
DC
92
%
* This is not an ambient temperature for operation. It is valid for a time of no more than 3 minutes, e.g. for cleaning purposes.
** The LED illuminates yellow if there is a functional Electronic-Key in the Electronic-Key adapter