FAQ
Phenomena
Cause of Malfunction
Troubleshot Method
No response from
control panel
operation
Accessories cannot
connect to control
panel
No response from
the control panel
by operating
remote control
RFID card/tag fail
to disarm
Touch keyboard fail
to make related
setting
Power switch is off
A/C Power failure
Lithium battery backup
power exhausted
Panel not in learning
status
Accessories not triggered
for learning
When learning, 3 beeps
are heard from panel
Remote control is not
learned to control panel
Out of range between
remote control and panel
RFID card/tag not connected
to the panel
Not logged onto the
setting menu.
Open battery compartment,
turn on the power
Contact local main power
supply bureau
Connect to main power with
adapter
Make sure the panel set in
learning status
Make sure the triggered
accessories transmit signal
to panel for learning
This means accessory has
been coded already
Follow the manual and connect
the remote control to panel
No more than 80 meters in
open area
(no interference)
Signal repeater could be added
Follow the work manual and
code RFID card/tag to the panel
Input the correct admin code,
press
and log on menu
setting
[ Enter ]
Specifications
Product Name
Model No.
Power Supply
Standby Current
Alarm Current
Backup Battery
Internal Siren Volume
Radio Frequency
PSTN/LCD/RFID Touch Alarm System
S2
Input: AC 110V-240V, 50/60Hz
Output: DC 12V 500mA, 6Wh
≤ 90mA
≤ 300mA
2 Cells of 3.7V 800mAh Li-ion Battery(BL-5B)
95dB
315MHz or 433MHz (±75KHz)
Maximum Stored Phone No.
Maximum Remote Controls
Maximum Sensors
Maximum RFID Tags
Maximum Event Logs
Housing Material
Operation Condition
Dimension (L x W x H)
6 alarm Phone No. and 2 CMS No.
10 pcs
50 pcs
50 pcs
150 events
ABS plastic
Temperature: -10°C~ 55°C
Humidity: 80%RH (non-condensing)
185x130x27mm
Wireless Remote Control
LED Indicator
Disarm
Arm
Stay
Panic
Arm
The delay sensors will be armed after delay time.
Press
button on the remote control, the system enters Arm state
when one beep is heard and the Arm LED Indicator lights on.
m
r
A
]
[
Note!
If Exit Delay is activated, all zones except the 24-hour zone will
enter Arm state after the set delay time.
Disarm
Press the
[Disarm ]
button on the remote control, the system enters
Disarm state when two beeps are heard and the Arm LED Indicator goes
out.
When alarm is activated, the siren will hoot. Press the
button,
the system is disarmed after two beeps are heard, and the Disarm LED
Indicator lights on. But the LED indicator of triggered zone keeps flashing
for further checking.
Press
button again, the alarming zone indicator goes out.
[Disarm ]
[Disarm ]
Home Mode
Press
button on the remote control, the system enters Home
Mode when one beep is heard and the Home Mode LED Indicator lights on.
All the Normal Sensors are armed except the Home Mode Sensors which
are disarmed so that users can move freely at home.
[ Stay ]
Mute Mode
Emergency Call
In any condition, once the
button on the remote control is pressed,
the system goes into emergent alarming state with siren hooting,
meanwhile the panel will autodial pre-stored alarm phone numbers.
S
O
S
]
[
When arm or disarm the system, the control panel will beep once or twice.
If siren beep is not needed, operationas follows :
Press
button on the remote control, then press
or
button. The system is armed or disarmed in mute without
disturbing other people.
[
]
[Arm ]
[Disarm ]
Stay