DataTrack System Planning and Installation Manual
Suspended Load Capacity
The maximum weight DataTrack can support per linear foot varies based on the distance between
mounting points. The following examples represent the maximum supported load based on various
distances between mounting points. The distance shown at the top of each illustration is the distance
between mounting points. The bottom of each illustration shows supported loads mounted onto the
track on 12 in (30.48 cm) centers.
Figure 5: Suspended load capacity
DMX Data Path
The following illustrations show examples of DMX data paths. These drawings are plan views, showing
the DataTrack system as if you were looking at it from above.
If you have additional DMX termination questions, please contact your local ETC representative.
For more information on DMX, visit the ETC website:
http://www.etcconnect.com/Support/Articles/DMX-512-Info.aspx
Distance between
mounting points
Maximum load
per foot
36 in (91.44 cm)
6.6 lb (2.99 kg)
18 in (45.72 cm)
11 lb (4.98 kg)
8 in (20.32 cm)
22 lb (9.97 kg)
CAUTION:
Data transmission will become unreliable if DMX is not installed according to
standard protocols.
CAUTION:
ETC recommends laying out the DMX data path for your track configuration BEFORE
ordering all track and couplers to ensure that no loops, stars, or Y’s are created that
would disrupt data transmission.
Note:
The DMX data line is only for low voltage with an approximate value of 50V 2A
maximum.
Note:
If DataTrack L-couplers, X-couplers, or T-couplers are required in your system, you
may need to disconnect one or more data-line connections to avoid data loops.
36”
12”
6.6 lb
6.6 lb
6.6 lb
6.6 lb
12”
12”
18”
18”
11 lb
11 lb
11 lb
11 lb
12”
12”
12”
22 lb
22 lb
22 lb
22 lb
12”
12”
12”
8” 8” 8” 8”