Installation
23
Wiring End Feeds
1:
Strip ground wire and connect to a 0.25 in (6.35 mm) female quick disconnect terminal (not
supplied). Push terminal onto tap clamp at ground plate. Use provided green wire for connecting
between tap clamp and feed connector terminal.
2:
Strip white Neutral 1 wire and connect to Neutral 1 terminal (N1) of feed connector. Clamp wire
using screw. See
Figure 18
.
Figure 18: End feed wiring
3:
Strip Hot 1 supply wire and connect to a 0.25 in (6.35 mm) female quick disconnect (not
supplied). Push onto the Line tap clamp on the current limiting circuit breaker.
4:
Connect load from current limiting circuit breaker to track feed connector terminal (L1) using
provided wire. See
Figure 18
.
5:
Follow the same instructions for Neutral 2 and Hot 2.
Feed connector
CIRCUIT
BREAKER
CIRCUIT
BREAKER
Line
Load
Line
Load
PE
N1
L1
P E
L2
N2
HOT2
N2
PE1
HOT1
N1