Installation
19
7:
After the mid feed has been fixed securely into place, wire the individual circuits and the earth
conductor as shown. When wiring the track, check that the earth conductor (green/yellow) and
the neutral conductors (white) are connected as indicated in
Figure 13
and
Figure 14
. Circuits 1
and 2 can be wired as required.
Figure 13: Wiring
Figure 14: Dismantling and insulation strip lengths
Figure 15: Dismantling and insulation strip lengths
Data lead
5-pole mains lead
Green / yellow
Power supply line
3/8 in
(9 mm)
2-1/2 in (65 mm)
Wire size:
Minimum = 16 AWG (1.5 mm
2
)
Maximum = 14 AWG (2.5 mm
2
)
5/32 in
(4 mm)
9/16 in
(15 mm)
Data line
Wire size:
Minimum = 23 AWG (0.25 mm
2
)
Maximum = 19 AWG (0.75 mm
2
)