background image

AIR TO WATER HEAT PUMP SYSTEM

INSTALLATION AND SERVICE MANUAL

13

EN

IMPORTANT INFORMATION AND WARNING

READ BEFORE INSTALLING THE UNIT. KEEP IN A SAFE PLACE. THE INFORMATION IN THE

FOLLOWING NOTES IS NEEDED FOR THE END OF LIFE DISPOSAL OR REUSE OF THE UNIT.

We are very sensitive to the environment and welcome the 2002/96/EC WEEE

(Waste Electrical and Electronic Equipment) Directive.

This product is compliant with EU Directive 2002/96/EC. It must be collected

separately after its use is completed and must not be disposed of as unsorted

municipal waste.

The objectives of the EU Directive 2002/96/EC are to tackle the fast increasing

waste stream of electrical and electronic equipment, increase the recycling of

electric and electronic equipment (“EEE”), and to limit the total quantity of waste

EEE (“WEEE”) going to disposal.

The crossed out wheeled bin symbol that is affixed to the product indicates that

this product may fall under the Directive.

The user is responsible for returning the product to the appropriate collection

facility as specified by your municipality or the distributor. In case of installation of

a new product, it may be possible to have the distributor pick up old WEEE

directly.

The producer, importer and distributor are responsible for collection and

treatment of WEEE, either directly or through a collective system. The distributor

for your country is shown below.

In case of violation of the Directive, sanctions are set in each country.

We are in general following the CECED interpretation which considers the

WEEE Directive applicable to Portable units, De-humidifiers, WRACs (Window

Room Air to Water Heat Pumps), Split systems up to 12kW, plug in refrigerators

and freezers.

Nevertheless, there may be differences among various member state laws.

In cases where national laws exclude some products from the WEEE scope,

those laws must be followed. In countries where these products are not covered

by the WEEE scope the WEEE obligations do not have to be followed.

The WEEE Directive does not apply to products sold outside the European

Community. In these cases the WEEE obligations do not have to be followed,

however compliance with any local regulations must be ensured.

For additional information please contact the municipal facility, the

shop/dealer/distributor/installer that has sold the product, or the producer.

Содержание HWS-1501CSHM3-E

Страница 1: ...SYSTEM INSTALLATIONS UND WARTUNGSANLEITUNG 26 DE SYST M TEPELN HO ERPADLA VZDUCH VODA SERVISN A MONT N MANU L 38 CZ CR LEVEG V Z H SZIVATTY RENDSZER FELSZEREL SI S SZERVIZEL SI K ZIK N 60 HU 72 GR LUF...

Страница 2: ...AL REGULATIONS PLEASE LEAVE THIS MANUAL WITH THE UNIT FOR FUTURE REFERENCE TECHNICAL SPECIFICATIONS Rated pressure 1 0 MPa 10 bar Test pressure hydraulic 1 5 MPa 15 bar Minimum recommended supply pres...

Страница 3: ...shcaft m b H Petersgasse 45 A 8010 Graz Austria Hungary Magyar AIRCOND Klimaanlagen Handelsgesellshcaft m b H Petersgasse 45 A 8010 Graz Austria Greece Carrier Hellas Aircondilioning S A 4g Andersen s...

Страница 4: ...nce 2 0 INSTALLATION GENERAL REQUIREMENTS 2 1 National Wiring Regulations may contain restrictions concerning the installation of these units in certain areas eg Bathrooms 2 2 The unit MUST be install...

Страница 5: ...ontinuously downward direction in a frost free environment 3 2 The water connections on the unit accept direct connection of 22mm outside diameter pipe nuts and olives are supplied for this purpose Th...

Страница 6: ...t on the front of the cover ISOLATE THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVER 4 3 The cylinder heater MUST be earthed 4 4 All electrical wiring should be carried out by a competent electrician a...

Страница 7: ...inder for long periods without draw off will become de oxygenated and potentially corrode the vessel material If the installation is to be left unused following installation and commissioning the wate...

Страница 8: ...remove the thermal cut out sensing bulb from its pocket on the cylinder heater by pulling outwards Be careful not to kink the capillary tube 6 6 Remove the element tail insulating shroud by pulling it...

Страница 9: ...released 8 0 USER INSTRUCTIONS 8 1 The water storage temperature at the Air to Water Heat Pump System Water Cylinder is set at the control panel of the Hydro Unit This can be set to give temperatures...

Страница 10: ...correct parts are ordered 9 2 DO NOT replace with parts not recommended by the manufacturer as this will invalidate your guarantee and may render the installation dangerous 9 3 Description Part No Cy...

Страница 11: ...sor 1 Cylinder heater thermal cut out has operated 2 Faulty water cylinder temperature sensor 1 Water storage temperature on Heat Pump Controller is set too high 2 Faulty water cylinder temperature se...

Страница 12: ...ervice within a period of 7 days If this is not the case it must either be drained or regularly flushed as required in the section Commissioning Warning 11 7 The unit is NOT guaranteed against damage...

Страница 13: ...or the distributor In case of installation of a new product it may be possible to have the distributor pick up old WEEE directly The producer importer and distributor are responsible for collection a...