11.0

GUARANTEE

For warranty details please contact your ESTIA Heat Pump supplier.
This water cylinder is guaranteed provided that:

11.1 The unit has been installed in accordance with these instructions and all

necessary inlet controls and safety valves have been fitted correctly.

11.2 Any valves or controls are of the manufacturers recommended type.
11.3 The unit has not been tampered with and has been regularly maintained as

detailed in these instructions.

11.4 The unit has been used only for heating potable water (max. 250mg/l chloride).
11.5 The unit has not been subjected to high chloride levels in the water supply or

incorrect disinfection methods.

11.6 Following commissioning the unit is put into service within a period of 7 days.

If this is not the case it must either be drained or regularly flushed as required

in the section “Commissioning – Warning”.

11.7 The unit is

NOT

guaranteed against damage by frost or due to build up of scale.

11.8 This guarantee does not affect the statutory rights of the consumer.

This guarantee

DOES NOT

cover the ESTIA Air to Water Heat Pump Outdoor

Unit or ESTIA Hydro Unit.

12.0

ENVIRONMENTAL INFORMATION

12.1 This product is manufactured from many recyclable materials. At the end of its

useful life it should be disposed of at a Local Authority Recycling Centre to

realise the full environmental benefits.

12.2 The insulation material is CFC/HCFC free expanded polyurethane foam with an

ozone depletion factor of zero.

The pace of product development is such that we reserve the right to change product

specifications without notice. We do, however, strive to ensure that all information in this

leaflet is accurate at the time of publication.

Содержание HWS-1501CSHM3-E

Страница 1: ...SYSTEM INSTALLATIONS UND WARTUNGSANLEITUNG 26 DE SYST M TEPELN HO ERPADLA VZDUCH VODA SERVISN A MONT N MANU L 38 CZ CR LEVEG V Z H SZIVATTY RENDSZER FELSZEREL SI S SZERVIZEL SI K ZIK N 60 HU 72 GR LUF...

Страница 2: ...AL REGULATIONS PLEASE LEAVE THIS MANUAL WITH THE UNIT FOR FUTURE REFERENCE TECHNICAL SPECIFICATIONS Rated pressure 1 0 MPa 10 bar Test pressure hydraulic 1 5 MPa 15 bar Minimum recommended supply pres...

Страница 3: ...shcaft m b H Petersgasse 45 A 8010 Graz Austria Hungary Magyar AIRCOND Klimaanlagen Handelsgesellshcaft m b H Petersgasse 45 A 8010 Graz Austria Greece Carrier Hellas Aircondilioning S A 4g Andersen s...

Страница 4: ...nce 2 0 INSTALLATION GENERAL REQUIREMENTS 2 1 National Wiring Regulations may contain restrictions concerning the installation of these units in certain areas eg Bathrooms 2 2 The unit MUST be install...

Страница 5: ...ontinuously downward direction in a frost free environment 3 2 The water connections on the unit accept direct connection of 22mm outside diameter pipe nuts and olives are supplied for this purpose Th...

Страница 6: ...t on the front of the cover ISOLATE THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVER 4 3 The cylinder heater MUST be earthed 4 4 All electrical wiring should be carried out by a competent electrician a...

Страница 7: ...inder for long periods without draw off will become de oxygenated and potentially corrode the vessel material If the installation is to be left unused following installation and commissioning the wate...

Страница 8: ...remove the thermal cut out sensing bulb from its pocket on the cylinder heater by pulling outwards Be careful not to kink the capillary tube 6 6 Remove the element tail insulating shroud by pulling it...

Страница 9: ...released 8 0 USER INSTRUCTIONS 8 1 The water storage temperature at the Air to Water Heat Pump System Water Cylinder is set at the control panel of the Hydro Unit This can be set to give temperatures...

Страница 10: ...correct parts are ordered 9 2 DO NOT replace with parts not recommended by the manufacturer as this will invalidate your guarantee and may render the installation dangerous 9 3 Description Part No Cy...

Страница 11: ...sor 1 Cylinder heater thermal cut out has operated 2 Faulty water cylinder temperature sensor 1 Water storage temperature on Heat Pump Controller is set too high 2 Faulty water cylinder temperature se...

Страница 12: ...ervice within a period of 7 days If this is not the case it must either be drained or regularly flushed as required in the section Commissioning Warning 11 7 The unit is NOT guaranteed against damage...

Страница 13: ...or the distributor In case of installation of a new product it may be possible to have the distributor pick up old WEEE directly The producer importer and distributor are responsible for collection a...

Страница 14: ...129 NOTES...