background image

WARNING:  If the information in this 

manual is not followed exactly, a fire or 

explosion may result causing property 

damage, personal injury or loss of life.

- Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do   

   not use any phone in your building.
•  Immediately call your gas supplier

   from a neighbor's phone. Follow the 

   gas supplier's instructions.
•  If you cannot reach your gas 

   supplier, call the fire department.

-

Installation and service must be

performed by a qualified installer, 

service agency or the gas supplier.

103798-02 - 10/13

AVERTISSEMENT.  Assurez-vous de 

bien  suivre les instructions données 

dans cette notice pour réduire au 

minimum le risque d'incendie ou 

d'explosion ou pour éviter tout 

dommage matériel, toute blessure ou 

la mort.

- Ne pas entreposer ni utiliser 

d'essence ni d'autres vapeurs 

ou liquides inflammables dans le 

voisinage de cet appareil ou de tout 

autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE 

ODEUR DE GAZ:

•  Ne pas tenter d'allumer d'appareils.
•  Ne touchez à aucun interrupteur.  Ne  

   pas vous servir des téléphones dans 

   le bâtiment où vous vous trouvez.
•  Appelez immédiatement votre 

    fournisseur de gaz depuis un voisin.  

    Suivez les instructions du 

    fournisseur.

•  Si vous ne pouvez rejoindre le 

    fournisseur de gaz, appelez le 

    service des incendies.

-

L'installation et I'entretien doivent 

être assurés par un installateur ou un 

service d'entretien qualifié ou par le 

fournisseur de gaz.

USER'S INFORMATION MANUAL

Series 3™

GAS - FIRED

 

BOILER

Summary of Contents for SERIES 3

Page 1: ...ENT Assurez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne...

Page 2: ...e RCF parts or attempt any service or repair work involving RCF without wearing the following protective gear 1 A National Institute for Occupational Safety and Health NIOSH approved respirator 2 Long...

Page 3: ...G Do not reset Blocked Vent Switch unless a qualified service agency has determined and corrected the cause of any blockage in the vent system or chimney 3 Blocked Vent Switch See Figure 1 A device wh...

Page 4: ...4 Figure 1 Control Locations...

Page 5: ...5 Figure 2 Operating Instructions NOTE YOUR BOILER IS EQUIPPED WITH A HONEYWELL VR8204 OR VR8304 GAS VALVE PLEASE FOLLOW THESE OPERATING INSTRUCTIONS...

Page 6: ...osed Checked Trial For Ignition Ignition Source Off Main Gas On Pilot Flame Proven Pilot Flame Not Proven Call For Heat Ends Standby Intelligent Hydronic Control can display typical Delay 60 Seconds I...

Page 7: ...medium hard blue enveloping 3 8 to inch of sensing probe If flame is yellow and lazy follow instructions TO TURN OFF GAS TO APPLIANCE see Figure 2 and contact qualified service agency 5 Check main bur...

Page 8: ...sale distributor Should you require assistance in locating a U S Boiler Company distributor in your area or have questions regarding the availability of U S Boiler Company products or repair parts ple...

Reviews: