E-SC 400 / 402 Classic Series Instruction Manual
Operating Parameters Customization
1. LED shows P1:
P1 is for setting your run time
. The run time will be determined from the time you had deter-
mined during the set up of the limit switches. Take that determined run time and add 1 second. So if it takes 10
seconds to get from closed to open between limit switches; set the run time to 11 seconds. The options are 0
-
99
seconds.
2. LED shows P2:
P2 is for setting your slow down time
. The gate opener will slow down to half speed after the
time set on P2 expires. If you wish to have the gate open and close faster make the slow down start time a longer
period of time. If you want to put less stress on the gears and gate set the slow time shorter to slow the momentum
sooner. The options will adjust to match the previously set run time.
NOTE:
motor must be in slow down to detect
limits
-
be sure this number does not exceed the time the motor take to move from one limit to the other.
3. LED shows P3:
P3 is the force setting
, the lower the number the easier the gate will reverse directions when it
meets resistance. "is number may have to be changed to a higher setting if your gate is obstructing unexpectedly.
The number should be set to the lowest number that still gives you reliable gate movement. The options are 0
-
32.
4. LED shows P4:
P4 is for setting a delay between leafs
if you have overlapping gates or a gate lock. The motor
wired into the master terminals (1) opens first if there is a delay and closes second.
NOTE:
If one leaf of a dual
gate ever reaches its end limit before the other leaf starts moving, the leaf that hasn’t started moving will not
begin: correct this by cycling the gates again and let it travel the full stroke or decrease the delay between leafs.
The options are 0
-
9 seconds delay.
5. LED shows P5:
P5 is the delay for the gate lock
– this option determines the length of time 24VDC
will be sent out of terminals E_LOCK. The options are 1
-
4 seconds.
6. LED shows P6:
P6 is the release for
automatic re
-
close
from the open position – this option needs to be
turned on using the dip switch on the board. The options are 0
-
99 seconds.
4.3
Содержание E-SC 400
Страница 4: ...Section 1 Review of Specifications Warnings and Tools...
Страница 5: ......
Страница 10: ...Section 2 Manual Operation and Installation...
Страница 11: ......
Страница 18: ...Section 3 Wiring Jumpers Receiver...
Страница 19: ......
Страница 26: ...Section 4 Start Up and Operation...
Страница 27: ......
Страница 33: ...Section 5 Troubleshooting and Accessories...
Страница 34: ......