E-S 1000H Series Instruction Manual
Accessories Wiring
6.1
Photo Eye, Safety Edge, Safety Loop:
Normally Closed (NC) of safety device
=
Photo terminal of PHOTO block on gate opener
control board.
Common (COM) or Ground (GND) of safety device
=
GND terminal of PHOTO block on
gate opener control board.
12V Power positive (+) or (12V) or (PWR) of safety device
=
V+ terminal of PHOTO block
on gate opener control board.
12V Power Negative (-) or (GND) or (PWR) of safety device
=
GND terminal of PHOTO
block on gate opener control board.
*Remove safety jumper from PHOTO terminal if using a safety device.
Solenoid Gate Lock:
Positive Lead of lock
=
A terminal of E_LOCK block on gate opener control board.
Negative Lead of lock
=
B terminal of E_LOCK block on gate opener control board
.
Magnetic Gate Lock: Magnetic gate locks must have their own power supply and their own
relay.
Coil of relay for magnetic lock
=
A terminal of E_LOCK block on gate opener control
board.
Coil of relay for magnetic lock
=
B terminal of E_LOCK block on gate opener control
board.
Connect positive lead of the power supply directly to the positive lead of the mag lock.
Connect negative lead of the power supply to the N/C terminal of the relay.
Connect the COM terminal of the relay to the negative lead of the mag lock.
Содержание E-S 1000H Series
Страница 1: ...INSTRUCTION MANUAL EstateSwing com E S 1000H Series Plug in Option...
Страница 4: ...E S 1000H Series Instruction Manual Section 1 Review of Specifications Warnings and Tools...
Страница 5: ......
Страница 10: ...E S 1000H Series Instruction Manual Section 2 Installation of Mounting Brackets...
Страница 11: ......
Страница 25: ...E S 1000H Series Instruction Manual Section 3 Gate Operator Mounting Wiring Motors Power...
Страница 26: ......
Страница 36: ...E S 1000H Series Instruction Manual Section 4 Start Up and Operation...
Страница 37: ......
Страница 43: ...E S 1000H Series Instruction Manual Section 5 Maintenance Troubleshooting Accessories...
Страница 44: ......