KING 24V

24Vdc

N 1800

AA14028

Peso max cancello

Poids maxi portail

Max gate weight

Max Torgewicht

Peso máx verja

400 kg / 880 lbs

KING 24V L

24Vdc

N 1800

AA14029

500 kg / 1100 lbs

ITALIANO pag. 05 / FRANÇAIS pag. 16 / ENGLISH page 27 / DEUTSCH pag. 38 / ESPAÑOL pag. 49

OPERATORE IRREVERSIBILE PER CANCELLI A BATTENTE

OPERATEUR IRREVERSIBLE POUR PORTAILS À BATTANT 

IRREVERSIBLE OPERATOR FOR LEAF GATES

TORANTRIEBE FÜR FLÜGELTORE

OPERADOR IRREVERSIBLE PARA CANCELAS DE BATIENTE

T2 24V

con / avec / with / mit

Summary of Contents for KING 24V

Page 1: ...00 AA14028 Peso max cancello Poids maxi portail Max gate weight Max Torgewicht Peso máx verja 400 kg 880 lbs KING 24V L 24Vdc N 1800 AA14029 500 kg 1100 lbs ITALIANO pag 05 FRANÇAIS pag 16 ENGLISH page 27 DEUTSCH pag 38 ESPAÑOL pag 49 OPERATORE IRREVERSIBILE PER CANCELLI A BATTENTE OPERATEUR IRREVERSIBLE POUR PORTAILS À BATTANT IRREVERSIBLE OPERATOR FOR LEAF GATES TORANTRIEBE FÜR FLÜGELTORE OPERAD...

Page 2: ...L DATA Max leaf length Max leaf weight Max travel Average opening time Operating speed Thrust force EEC Power supply Motor capacity Power absorbed Daily operations suggested Service Guaranteed consecutive cycles Grease Weight of electroreducer Noise Volume Operating Temperature Protection m 3 5 4 5 kg 400 500 mm 345 475 s 14 27 29 38 m s 0 0125 N 1800 24V W 118 A 5 4 n 150 90 n 200 14s Bechem RHUS...

Page 3: ... If there is an iron pillar you can weld the attachment directly If there is a cement pillar you can use the fixing plate as in Fig 5 which is fastened with 4 Fischer screws of Ø 8 mm There is also the possibility to cement the attachment welding an anchor at its base Fig 6 Naturally you have to respect predetermined fixing measures Afterwards you must weld the other actuator s attachment to the g...

Page 4: ...s must be checked That the gate is endowed with appropriate handles That these appropriate handles are placed so to avoid safety risks for the operator That the physical effort necessary to move the gate leaf should not be higher than 225 N for doors gates for private dwellings and 390N for doors gates for commercial and industrial sites values indicated in 5 3 5 of the EN 12453 norm MAINTENANCE T...

Page 5: ...5 B 115 200 140 815 115 27 B 105 190 190 945 150 26 D 160 214 120 945 150 20 D L Min Max a A max T sec B C D E 1 1 80 1 81 2 20 2 21 2 50 2 51 3 00 3 01 3 50 3 51 4 00 110 20 90 140 815 90 20 A 100 130 815 90 21 A 110 140 815 115 24 B 130 140 945 120 29 C 160 150 945 120 19 C 160 230 945 150 22 D L Min Max a A max T sec B C D E ANT ANT KING 24V KING 24V KING 24V KING 24V KING 24V KING 24V L KING 2...

Page 6: ...ENNA ANTENNA BRAIDING CLOSE OPEN STOP FUSE T 2 A PHOTOCELLS STEP BY STEP COMMON COMMON 24Vdc 0 8A 15 for ACCESSORY SUPPLY 24Vdc 0 8A 15 for AUTOTEST SAFETY STRIPS BLINKER 24Vdc 20W LED R 2 2K 1 4W ELECTRIC LOCK PEDESTRIAN SAFETY STRIPS POWER SUPPLY 230Vac 50 Hz TRANSFORMER M1 M2 ...

Page 7: ...amming DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Connector dedicated to the factory programming only CRX control board DO NOT REMOVE ANY JUMPER OTHERWISE THE OPERATOR WILL NOT WORK Built in radio module model CRX or connector for radio receiver RIB 24 Vdc supply Connector for charge card of 24Vdc battery code ACG4648 Trimmer for high speed adjustment operations Trimmer for low ...

Page 8: ...gate opening M1 green DL5 gate closing M1 red DL6 automatic closing indicator red DL7 photocell contact NC red DL8 sensor contact NC red DL9 STOP button NC red DL10 radio code program green FUSES Fuse 1 T 8A MOTOR PROTECTION FUSE F1 T 2A TRANSFORMER PROTECTION FUSE on the outside of the T2 24V board C MOTOR ROTATIONAL DIRECTION CONTROL 1 Set DIP 1 to ON LED DL1 starts flashing 2 Press and hold the...

Page 9: ... PROG button for 5 seconds Memory cancellation is indicated by two flashes of green LED DL10 4 The red LED DL1 remains active and you can add new codes as shown above 5 Reset DIP 1 to OFF and DIP 2 to OFF 6 End of procedure INDICATOR MEMORY FULL OF RADIO CODES FOR TOTAL OPENING Indication only when gate is stationary 1 Set DIP 1 to ON and then DIP 2 to ON 2 The green LED DL10 flashes 6 times when ...

Page 10: ... movement in front of the photocells is deactivated N B Please check photocell operation at least every six months EDGE SAFETY STRIP COM EDGE If engaged during opening reverses the motion when closing If engaged when closing reverses the motion when opening If it remains engaged again it performs a further reversal after 2 seconds then performs an additional short reversal and then gives the senso...

Page 11: ...eceiving Frequency 433 92 MHz Impedance 52 OHM Sensitivity 2 24µV Pick up time 300ms Drop time 300ms All inputs must be used as clean contacts because the power is generated internally secure power to the board and is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage Any external circuits connected to the outputs of the control panel must be made in ...

Page 12: ...0V ac dc code ACG6099 NOVA Wi Fi PHOTOCELLS WITHOUT WIRES code ACG8037 PAIR OF COLUMS NOVA code ACG8039 TOUCH Wi Fi STRIP WITHOUT WIRES code ACG3016 SPARK Wi Fi BLINKER WITHOUT WIRES code ACG7064 LATERAL SUPPORT code ACG7042 BLOCK Wi Fi KEY SELECTOR WITHOUT WIRES code ACG6098 Discover the only wireless automation devices at www ribind it SET SOLAR AMPLIFIER Interface for 50W solar panels code AD00...

Page 13: ...fissaggio colonna KING L Piatto attacco cancello KING L Attacco cancello serie KING Angolare attacco a colonna 2 pezzi KING Piastra attacco colonna KING L Cuscinetto motore 6005ZZ Condensatore 10µF 450V x serie 230V 50 Codice Denominazione Particolare CEL1426 CME1166 CME1299 CME2042 CME2041 CME8996 CME9129 CME9130 CME9785 CME9868 CMO2515C CPL1087 CPL1157 CPL1161 CRS62042R CTC1004 CTC1008 CTC1119 C...

Page 14: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...