1/5/2007
EAG Gateway Series Administration Guidelines
MAG-06007 Rev. A
Since straight cable is used, the connector for the other end of the cable can be made the same way
using RJ45 connector.
Note:
Please use shielded CAT-5 cable when option is available for better signal transmission quality.
After the Ethernet cable is ready, one end of the cable can connect to EAG and the other end
connect to a HUB or IP network. Please check the Ethernet LED status: yellow means
connecting in progress and green means in operation.
4.6.3
Connecting FXS Cable
EAG has an FXS interface that connects to analog phones.
Connect one end of the FXS cable to the EAG FXS interface, and connect the other end to phones,
faxes, or PBXs, as shown in Figure 13.
Figure 13. Connect with FXS Cable
Note:
To avoid connecting to the wrong interface, please check the identity on the interface before
connecting the cable.
4.7 Connecting Power Supply
EAG uses high efficient switching power supply module. Single module can power up the unit with full
load. The second power supply module can also be installed to provide redundancy. The switching
power supply module has the following characteristics:
Input Voltage Range: 100~240V
Output multiple independent Direct Currents: -70 for ringing and off-hook; -24V for talking battery; +5V
for ringing SLIC; 3.3V for logic device.
Before connecting to the power outlet, it is suggested that tri-phase power outlet be used and ground
be properly connected.
Please follow the procedure when connecting to the power source:
1.
Turn the switch for the power outlet to OFF position.
23