IPS Belt Cleaner
18
19/11/2021
6.3 Maintenance Procedure
To access the blade cartridge for maintenance, first de-adjust the cleaner by shutting off the
air supply at the individual isolation valve for the cleaner in the Air Tensioner Control Box.
The cleaner will automatically retract from the belt. When fully retracted, close or re-fit the
Control Box lid. This will prevent re-pressurising of the Air tensioners during maintenance.
Next remove the retaining pin securing the blade cartridge to the operator end of the
mainframe. Grasp the handle and pull the blade cartridge off the mainframe and away from
the mount bracket. Completely remove the blade cartridge from the mainframe, and place it
in a suitable position for maintenance work to be carried out.
Refer to the Routine Maintenance Section 8.
Re-assembly is the reverse of the above procedure. Once the blade cartridge has been re-
fitted and secured, open the isolation valve in the Control Box to pressurise and automatically
adjust the cleaner to the belt. Check that the air pressure is to specification and adjust if
necessary.
Содержание InLine 20-Ten Series
Страница 1: ...IPS Belt Cleaner 1 19 11 2021 IPS Belt Cleaner Installation and Operation Manual...
Страница 24: ...IPS Belt Cleaner 24 19 11 2021 SECTION 11 INSTALLATION DRAWINGS...
Страница 25: ...IPS Belt Cleaner 25 19 11 2021...
Страница 26: ...IPS Belt Cleaner 26 19 11 2021 SECTION 12 EXPLODED PARTS DRAWINGS...
Страница 27: ...IPS Belt Cleaner 27 19 11 2021...
Страница 28: ...IPS Belt Cleaner 28 19 11 2021...
Страница 29: ...IPS Belt Cleaner 29 19 11 2021...
Страница 30: ...IPS Belt Cleaner 30 19 11 2021...
Страница 31: ...IPS Belt Cleaner 31 19 11 2021...
Страница 32: ...IPS Belt Cleaner 32 19 11 2021...