IPS Belt Cleaner
17
19/11/2021
6.2 Adjustment Procedure
Adjusting the Air Tensioned In-Line cleaner is simply a matter of supplying air at the
appropriate pressure to the tensioner air bags. Refer to the table below for recommended air
pressures.
If using an
ESS
Air Tensioner Control Box, connect the plant air line to the lockable ball valve
on the outside of the enclosure, and check that all air connections are in place as per section
4, step 8 of this manual, figure 6 above and the
ESS
Control Box manual. Turn on the air
supply and open the lockable ball valve. Open the individual isolation valve for this cleaner in
the
ESS
Control Box to pressurise the tensioner. The cleaner will automatically raise, and the
blades will contact the belt.
Adjust the pressure to the required level via the regulator unit inside the Control Unit. The
regulator is self-relieving, so the pressure will stabilise, but it is advisable to wait a short while
after each adjustment to allow excess pressure to bleed.
Once the correct pressure has been achieved, lock the regulator adjustor, and replace the lid
on the enclosure.
Table B. Recommended Air Pressure
PRESSURES
BELT WIDTH
kPa
PSI
450
34
5
600
41
6
750
55
8
900
62
9
1050
76
11
1200
83
12
1350
97
14
1500
103
15
1600
110
16
1800
124
18
2000
138
20
2200
138
20
2400
138
20
Содержание InLine 20-Ten Series
Страница 1: ...IPS Belt Cleaner 1 19 11 2021 IPS Belt Cleaner Installation and Operation Manual...
Страница 24: ...IPS Belt Cleaner 24 19 11 2021 SECTION 11 INSTALLATION DRAWINGS...
Страница 25: ...IPS Belt Cleaner 25 19 11 2021...
Страница 26: ...IPS Belt Cleaner 26 19 11 2021 SECTION 12 EXPLODED PARTS DRAWINGS...
Страница 27: ...IPS Belt Cleaner 27 19 11 2021...
Страница 28: ...IPS Belt Cleaner 28 19 11 2021...
Страница 29: ...IPS Belt Cleaner 29 19 11 2021...
Страница 30: ...IPS Belt Cleaner 30 19 11 2021...
Страница 31: ...IPS Belt Cleaner 31 19 11 2021...
Страница 32: ...IPS Belt Cleaner 32 19 11 2021...