IPS Belt Cleaner
12
19/11/2021
Step 9.
With the cleaner tensioner in the fully retracted position, the cleaning blades
should be approximately 15-20mm clear of the underside of the belt for Air
Tensioned models and 5-10mm clear for Spring Tensioned models. This
distance should be equal across the width of the belt.
If necessary loosen the bolts and adjust the mounts up or down in the slots to
achieve this clearance. Once all clearances are correct, thoroughly check all
mounting and locking screws to ensure they are tight, and the cleaner is
secured.
Step 10.
For the Air Tensioned model only, connect the air tube to the fittings in the Far
Side airbag, on the underside of the mount bracket. See figure 6, section 6.
Pass the tube through the mainframe to the Operator End. Connect the tube to
the Tee air fitting in the Operator Side airbag, adjusting the tube length to suit
by cutting.
Connect the other side of the Tee fitting to the incoming regulated compressed
air supply from the
ESS
Air Tensioner Control Box. Connect the plant air
supply to the inlet side of the Control Box. Refer to the installation manual for
the
ESS
Control Box for further set-up instructions.
Installation is now complete, and the cleaner is ready to be adjusted
against the belt.
Содержание InLine 20-Ten Series
Страница 1: ...IPS Belt Cleaner 1 19 11 2021 IPS Belt Cleaner Installation and Operation Manual...
Страница 24: ...IPS Belt Cleaner 24 19 11 2021 SECTION 11 INSTALLATION DRAWINGS...
Страница 25: ...IPS Belt Cleaner 25 19 11 2021...
Страница 26: ...IPS Belt Cleaner 26 19 11 2021 SECTION 12 EXPLODED PARTS DRAWINGS...
Страница 27: ...IPS Belt Cleaner 27 19 11 2021...
Страница 28: ...IPS Belt Cleaner 28 19 11 2021...
Страница 29: ...IPS Belt Cleaner 29 19 11 2021...
Страница 30: ...IPS Belt Cleaner 30 19 11 2021...
Страница 31: ...IPS Belt Cleaner 31 19 11 2021...
Страница 32: ...IPS Belt Cleaner 32 19 11 2021...