Instalacion_10 v1.2.fm
- 10/1
2
/07
INSTALLATION
68
Installation manual
4
FINAL PREPARATION
Connections and checks
User instruction
1
Carry out the installation and the connections for all
the elements of the facility, in line with the control
panel instructions.
n
Except in VUS models (which have a patented
safety device), it is necessary to install
additional protection devices in order to fulfil
the requirements of standard EN 12453:2000.
2
Check that the mechanism is correctly regulated.
n
The opening and closing pressures must be
adjusted to respect the values indicated in
standard EN 12453:2000, as shown in the
attached chart. The measurements must be
made in line with the method described in
standard EN 12445:2000.
For models without a patented safety device,
the door should not exercise a force in excess
of 150N (15kg).
3
Check the operation of all the installation elements,
especially the protection systems and the manual
operation unlocking system.
1
Instruct the user with regards to the use and
maintenance of the facility and provide him/her with
the use manual.
2
Point to the door, showing that it opens
automatically, and indicating how to operate it
manually. Where appropriate, indicate that
operation is using the remote control.
F
d
< 400N in spaces between 50mm and 500mm
F
d
< 1400N in spaces> 500mm
I
L