FUNCTIONING MODES
Automatic mode (
F101
)
Opening:
this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
•
Collective opening:
the control board does not
obey the key commands during opening
(configurable in the advanced options menu, see
“Advanced Functions Programming (D1= “A”)” on
page 62).
Standby
: t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
•
If the key device or the photocells are activated
during standby, standby time restarts (configurable
in the advanced options menu, see “Advanced
Functions Programming (D1= “A”)” on page 62.
Closing:
the closing operation starts automatically
once standby time is finished.
If, during closing, the key device is activated, the
gate inverts operation direction and opens
completely.
Step-by-step mode (
F102
)
Opening:
this begins by activating the key device
(transmitter, magnetic key, key switch, etc).
•
Step-by-step opening:
if the key device is operated
during opening, the gate halts (programmable in
the advanced options menu, see “Advanced
Functions Programming (D1= “A”)” on page 62).
The display shows pause situation
PA
.
The gate closes when the key device is activated again.
Standby:
the gate remains open indefinitely until the
key device is operated.
Closing:
the closing process starts up by using the key
device.
If, during closing, the key device is activated, the
operator inverts the movement and the gate opens.
5
OBSTACLE DETECTION FUNCTIONING
The gate can detect an obstacle in two ways:
A- Detection by photocell or strip
Opening safety device (SG.A)
During opening
: if, during opening, the opening
safety device (SG.A) is activated, the gate inverts
operation direction and slightly closes. The gate
remains on standby until a key command is received
and the display shows
PAC4
.
During closing:
if, during closing, the opening safety
device (SG.A) is activated, the gate continues to close.
Closing safety device (SG.C)
During opening:
if, during opening, the closing safety
device (SG.C) is activated, the gate continues to open.
During closing:
if the closing safety device (SG.C) is
activated during closing, the shutter gate inverts
operation direction and opens completely. The display
shows
OPC5
.
B- Direct detection (built-in safety)
During opening
If, during opening, the gate collides with an obstacle, it
inverts operation direction and slightly closes. The gate
remains on standby until a key command is received
and the display shows
PAF1
or
PAE1
. The gate closes
when the key device is used.
During closing
If, during closing, the gate collides with an obstacle, it
inverts operation direction and opens completely. The
display shows
OPF1
or
OPE1
.
Содержание Dolfin DOS424E
Страница 2: ......
Страница 26: ...Actualizado 23 5 11 MANTENIMIENTO Y DIAGN STICO DE AVER AS 22 Manual de instalaci n...
Страница 48: ...Mis jour 7 9 11 MAINTENANCE ET DIAGNOSTIC DE PANNES 44 Manuel d installation...
Страница 70: ...Updated 5 9 11 MAINTENANCE AND DIAGNOSIS OF FAILURES 66 Installation Manual...
Страница 92: ...Actualizado 7 9 11 MANUTEN O E DIAGN STICO DE AVARIAS 88 Manual de instala o...
Страница 114: ...Erreka B Ibarreta s n 20577 Antzuola Gipuzkoa T 943 786 150 F 943 787 072 info erreka com www erreka com MSM 038 02...