2400VS SERIES
Erie Water Treatment Controls – Belgium
Page 5
Brine refill flow control
Together with the time of the fast rinse/brine refill cycle, the brine refill flow control determines
the quantity of refill to the brine tank, independent of the inlet pressure:
flow control x cycle time = quantity of refill
Do mind that the fast rinse/brine refill cycle can only be set by increments of 1 min!
!!! The following tables are only an indication and are valid for a brine valve with a refill rate that equals or
exceeds the rate of the refill flow control.
Brine refill F.C.
Program: 3
e
cycle
Quantity of refill
Nr.
Gal/min
(L/min)
min
L (±10 %)
A
0,25 (1,0)
4
3,8
A
0,25 (1,0)
6
5,7
A
0,25 (1,0)
8
7,6
A
0,25 (1,0)
10
9,5
B
0,5 (1,9)
6
11,4
B
0,5 (1,9)
8
15,1
B
0,5 (1,9)
10
18,9
D
1,0 (3,8)
6
22,7
D
1,0 (3,8)
8
30,3
D
1,0 (3,8)
10
37,9
D
1,0 (3,8)
12
45,4
/
K
v
= 0,27
/
/
Tank
Brine refill F.C.
inch
mm
Nr.
7
178
A-B
8
203
A-B
9
229
B
10
254
B-D
12
305
D
13
330
D
14
356
D
16
406
/
Содержание 2400VS Series
Страница 1: ...A Division of Aquion Inc 2400VS SERIES Technical Manual...
Страница 3: ...A Division of Aquion Inc Art Nr Tech_Man ENG 2400VS 2013 06...
Страница 4: ......
Страница 23: ...2400VS SERIES Erie Water Treatment Controls Belgium Page 19...
Страница 28: ...2400VS SERIES Erie Water Treatment Controls Belgium Page 24 Exploded Views Part Numbers Electronic timer...
Страница 30: ...2400VS SERIES Erie Water Treatment Controls Belgium Page 26 Valve body...
Страница 33: ......