Loss of water pressure
Cause
Solution
1.
Mineral or iron build-up in resin tank
1.
Clean resin bed and control valve; increase regeneration
frequency
2.
Plugged lower and/or upper distributor 2.
Verify that distributors are free of debris
3.
Crushed lower and/or upper distributor
3.
Replace distributor(s)
Drain flows continuously
Cause
Solution
1.
Defective PCB
1.
Replace PCB
2.
Defective micro switch
2.
Replace micro switches
3.
Defective drive motor
3.
Replace drive motor
4.
Valve body and timer out of
synchronisation
4.
Synchronise valve body and timer
5.
Leak between rotor and seal disk
5.
Verify or replace rotor and seal disk