Eridan IP535-07ea-RS Скачать руководство пользователя страница 2

1.

 

APPLICATION OF THE PRODUCT 

This  Operation  manual  (OM)  covers  the  explosion-proof  fire  manual  call  point  IP535-07e  in 

IP535-07ea-RS  modification  -  explosion-proof  addressable  manual  fire  call  point  with  support  of 
ModBus RTU protocol (further – the call point, the product). 

The call point is designed for generation of fire alarm signal or launch of fire extinguishment by 

means of pulling out the driving element in explosive areas or general industrial purpose areas. 

The  call  point  can  be  used  in  fire  alarm  and  fire-extinguishing  systems  for  generation  and 

sending  of  electric  alarm  signals  to  fire  alarm  control  panels  (FACP)  or  in  automatic  process 
control systems for transferring of digital data signal via standard communication channel RS-485 
with Modbus RTU protocol. 

The call point can be operated in varied climatic areas (NF1, F1, MU1, etc.) within temperature 

range from -60°С to +85°С, placement category 1, atmosphere type II or III as per GOST 15150-
69, protection degree of the call point's casing against dust and water corresponds to IP66/IР67 as 
per GOST 14254-96 (IEC 60529:2013). 

The  call  point  meets  the  safety  requirements  for  explosion-proof  equipment  as  per  TR  CU 

012/2011 and Technical Regulation on Fire Safety Requirements TR EAEU 043/2017. 

The call point has explosion-proof protection level, explosion-proof protection type ‘explosion 

proof casing ‘d’ and explosion proofness marking as per GOST 31610.0-2014 (IEC 60079-0:2011): 

 

1Ex db IIC T6 Gb 

Ex tb IIIС Т85°C Db 

The  explosion-proof  manual  fire  call  point  must  be  used  with  cable  glands  and  plugs  of  the 

manufacturer  or  other  certified  cable  glands  and  plugs  that  provide  explosion  protection  type 
‘explosion-proof  enclosure’  and  explosion  protection  level  1.  The  protection  degree  (IP)  and  the 
operating  temperature  range  of  cable  glands  should  correspond  to  the  operating  conditions  of  the 
call point. 

The call point can be installed in class 1 and 2 indoor explosive areas and outdoor installations 

according  to  the  assigned  explosion  proofness  marking,  TR  CU  012/2011,  GOST  IEC  60079-14-
2013,  the  Classification  of  Chapter  7.3  of  the  Electrical  Installation  Code  (version  6)  and  other 
regulations setting forth application of electrical equipment in explosive areas. 

The  environment  may  contain  explosive  mixes  of  gases  and  vapors  with  air,  groups  IIA,  IIB 

and IIC as per GOST IEC 60079-10-1-2013, GOST R IEC 60079-20-1-2011 as well as combustible 
dusts, groups IIIA, IIIB and IIIC as per GOST IEC 60079-10-2-2011. 

The call point can be manufactured in the following modifications: 
a)

 

addressable  call  point  IP535-07ea-RS-A  in  explosion-proof  version  designed  as  a  class  A 

call point as per GOST R 53325-2012 

b)

 

addressable  call  point  IP535-07ea-RS-B  in  explosion-proof  version  designed  as  a  class  B 

call point as per GOST R 53325-2012 

c)

 

addressable  remote  start  device  IP535-07ea-RS-START  in  explosion-proof  version 

designed as a class B call point as per GOST R 53325-2012. 

Production  of  the  call  points  is  only  possible  subject  to  availability  of  valid  certificates  of 

compliance with fire safety and equipment explosion proofness requirements. 

The call points designed for operation on vessels classified by the Russian Maritime Register of 

Shipbuilding (further – the RS) must be manufactured and tested under technical supervision of the 
RS. The need for such supervision must be specified when placing the order. 

The call points IP535-07ea-RS are not measuring devices. 
Connection diagrams of the call point are shown in Annex B. 
The  call  point  supports  operation  via  Modbus  RTU  protocol  in  driven  mode  and  meets  the 

requirements of the following specifications: 

1)

 

MODBUS Application Protocol Specification V1.1b3 

Содержание IP535-07ea-RS

Страница 1: ...nel e mail market eridan zao ru http www eridan ru 2 26 30 50 121 Explosion Proof Addressable Manual Fire CALL POINT IP535 07ea RS Modbus RTU protocol Operation Manual 4371 006 43082497 04 04 2021 EXP...

Страница 2: ...degree IP and the operating temperature range of cable glands should correspond to the operating conditions of the call point The call point can be installed in class 1 and 2 indoor explosive areas an...

Страница 3: ...vice UDP 4 X4 designation of the version variant for the IP535 07ea RS call point call point class as per GOST R 53325 2012 A class A one step activation B class B activation by performing several act...

Страница 4: ...l point are provided via the four wire communication line 2 wires RS 485 line Modbus RTU protocol 2 wires electrical power supply The call points must be connected to communication line in parallel wi...

Страница 5: ...r normal climatic conditions withstands a sinusoidal alternating voltage of 0 55 kV 50 Hz during one minute 2 17 Electrical resistance of insulation between the connected output conductors and the cal...

Страница 6: ...otection degree IP and the operating temperature range of cable glands should correspond to the operating conditions of the call point By agreement with the customer call points can be equipped with d...

Страница 7: ...al power supply The call points must be connected to communication line in parallel with strict observation of polarity Connection diagrams of the call point are shown in Annex B In order to configure...

Страница 8: ...s will cause the instrument to receive the Activated signal from the call point device it will display the corresponding message and will send back to the call point an acknowledgement of successful s...

Страница 9: ...explosion protection type explosion proof enclosure and explosion protection level 1 The protection degree IP and the operating temperature range of cable glands should correspond to the operating co...

Страница 10: ...cover and the body 6 12 The call point must be sealed after installation 7 SAFETY PROVISIONS 7 1 Compliance with the safety rules is mandatory for safe operation and use of the call points 7 2 Any wor...

Страница 11: ...n of the call point at the facility must follow the predesigned plan taking into consideration all the requirements hereof 8 5 Prior to installation of the call point at the site remove plugs from the...

Страница 12: ...ible 8 21 Check the completed installation by drawing attention to the correctness of the connections the presence of all fastening and locking elements and their correct installation 8 22 Close the c...

Страница 13: ...r and its address Customs Union conformity mark name or logo of certification authority and number of the certificate of compliance 9 3 The sequence of marking records is determined by the manufacture...

Страница 14: ...1 0 h 10 5 It is strictly prohibited to operate the call point with damaged explosion proof parts and any other defects 10 6 Opening of the call point cover and inspection are only allowed after all...

Страница 15: ...he fire device 11 3 In case of other more complicated failures their elimination can be carried out only at the manufacturer s factory Eridan JSC 11 4 In case of the call point s failure there are no...

Страница 16: ...al rules of cargo transportation 12 3 During transportation the requirements of the manipulation signs on the transportation packages must be strictly complied with During cargo handling and transport...

Страница 17: ...omer 14 CLAIM INFORMATION 14 1 Claims regarding quality of the call point are accepted upon submission of the call point this technical certificate and the report on hidden defects 14 2 The manufactur...

Страница 18: ...ed by the Certification Authority OS POZHTEST of FGBU VNIIPO of Emercom of Russia Certificate of compliance with the Technical Regulations of the Customs Union TR CU 020 2011 EAEU No RU RU 40 00693 20...

Страница 19: ...holes for sealing with the driving element the arrows on the call point nameplate must face vertically down as per the figure 7 lens 15 disk 23 24 washer 21 bolt 27 magnet 28 sealing ring 29 LED 30 b...

Страница 20: ...20 b Appearance of the call point IP535 07ea B...

Страница 21: ...3 removable element 4 body 6 cover the arrows on the device nameplate must face vertically down as per the figure 7 lens 8 protective element 15 disk 23 24 washer 21 bolt 27 magnet 28 sealing ring 29...

Страница 22: ...ble in cable gland KVBU 1 sheath wall maximum diameter for cable entry Dc 12 mm 2 cable insulation 3 sealing ring along the cable wrapping L 20 mm in uncompressed condition 4 washer 5 lock nut 6 union...

Страница 23: ...exceeding 2 5 mm is not allowed 2 insert the wire free from insulation into the inlet of the terminal 3 clamp the wire by releasing the terminal wrench or the screwdriver after that self disconnectin...

Страница 24: ...2 Terminal board of the call point IP535 07ea RS Table 5 The terminals designation for the call point IP535 07ea RS No of socket No of contact Designation of contact Description 1 1 6 Usup Feed throug...

Страница 25: ...of the contacts of the relay R2 Failure Terminal RTERM and additional RADD resistors are selected in accordance with FACP operation manual Install the jumper in terminals 3 7 of socket 2 of the call p...

Страница 26: ...f the call point Figure 5 Diagram of connection of the call point to fire alarm loop activated by closing The off position of the relay R1 Activated is configured as normally closed NC The call point...

Страница 27: ...ask and OR mask 0 17 reading and recording of various storage registers 0 2B 0 0E reading of device identifier processing of broadcast packets with a slave device address equal to 0 There is no respon...

Страница 28: ...ersion 0 65535 3 0x0008 8 0 03 UINT Serial number Lo 0 65535 0x0009 9 0 03 UINT Serial number Hi 0 65535 0x000A 10 0 03 UINT Device general status 1 6 1 booting 2 test 3 normal 4 acknowledgement reque...

Страница 29: ...t is activated 0 Installed 9 15 Reserve 14 Table 8 Configuration register register 50 0 0032 Bit No Designation Note 0 1 Activated signal is registered before reveiving a reset command status registra...

Отзывы: