of the Electrical Installation Code (version 6). The possible explosive areas of dust atmospheres of 
the call point application are in accordance with the requirements of GOST IEC 60079-10-2-2013. 

6.3.

 

Before  mounting  the  call  point,  its  visual  inspection  is  necessary.  Please  check  if  the 

casing  is  intact,  and  also  check  availability  of  the  following:  sealing  elements  of  the  cable  glands 
and the cover, explosion proofness marking and the warning ‘Unplug before opening’. 

6.4.

 

No  dents,  mechanical  damage  and  corrosion  are  allowed  on  explosion-proof  surfaces  of 

units and parts to be disassembled. 

6.5.

 

Power  supply  to  the  call  point  must  be  arranged  in  strict  compliance  with  the  effective 

Manual  for  installation  of  the  equipment  of  power  supply  and  lighting  circuits  in  explosive  areas 
VSN 332-74 and with this Operation Manual. 

6.6.

 

In explosive areas, use of cables with polyethylene insulation or sheath is not allowed. 

6.7.

 

Installation  works  must  be  carried  out  when  power  supply  lines  are  disconnected.  The 

electrical connection diagram must comply with the Figures of Annex B. 

6.8.

 

The  call  point  body  must  be  grounded  by  means  of  a  copper  wire  with  min.  1.5  mm 

diameter. The grounding wire must have a reliable contact with the body and the grounding circuit. 

6.9.

 

Sealing  of  cable  in  the  input  device  socket  must  be  performed  with  extreme  care,  since 

explosion proofness of the input device depends on that. 

6.10.

 

In  case  one  input  device  only  is  used  in  the  call  point,  vacant  input  device  must  be 

plugged securely by means of the plug (Figure 2e, Annex A). 

6.11.

 

Anti-corrosion heat resistant grease as per GOST 9433-80 must be restored on explosion-

proof surfaces of the cover and the body. 

6.12.

 

The call point must be sealed after installation. 

7.

 

SAFETY PROVISIONS 

7.1.

 

Compliance  with  the  safety  rules  is  mandatory  for  safe  operation  and  use  of  the  call 

points. 

7.2.

 

Any works related to installation, inspection, maintenance and operation of the call points 

must  be  only  permitted  to  persons  that  have  undergone  the  professional  and  safety  trainings, 
certification by the certifying board and have been acquainted with this operation manual. 

7.3.

 

Any works related to maintenance of the call point in explosive area that involve opening 

of its cover must be carried out after powering down the device. 

7.4.

 

The  call  points  are  safe  for  the  personnel  during  installation,  repairs  and  routine  work 

both in good condition and in case of any possible malfunctions. 

7.5.

 

Electric  shock  hazard  protection of  the  call  point  corresponds  to Class  III  as  per  GOST 

12.2.007.0-75. 

7.6.

 

Operators are responsible for work safety. 

8.

 

PROCEDURE OF INSTALLATION AND OPERATION 

8.1.

 

After receiving the call point, prepare the place of its operation, open the package, check 

the scope of supply according to clause 3 of the technical certificate and the packing list. If the call 
point  was  subjected  to  negative  temperatures  before  opening  the  package,  keep  it  at  room 
temperature for minimum four hours. 

8.2.

 

Carry  out  visual  inspection  of  the  call  point;  make  sure  there  are  no  visible  mechanical 

damages, and the explosion marking is available. 

8.3.

 

Check the call point’s functionality, in order to do that: 

a)

 

Establish  the  check  circuit  in  accordance  with  Annex  B  in  order  to  check  the  addressable 

call  point  functionality.  If  necessary,  connect  the  actuating  relays  R1  and  R2  of  the  call  point. 
Exchange  check  software,  for  example,  Lectus  Modbus  OPC/DDE  server  (v.  3.9  and  above)  or 
Modbus Poll (v.5.0.1 and above), must be installed on the PC. 

b)

 

Apply voltage to the call point. 

Содержание IP535-07ea-RS

Страница 1: ...nel e mail market eridan zao ru http www eridan ru 2 26 30 50 121 Explosion Proof Addressable Manual Fire CALL POINT IP535 07ea RS Modbus RTU protocol Operation Manual 4371 006 43082497 04 04 2021 EXP...

Страница 2: ...degree IP and the operating temperature range of cable glands should correspond to the operating conditions of the call point The call point can be installed in class 1 and 2 indoor explosive areas an...

Страница 3: ...vice UDP 4 X4 designation of the version variant for the IP535 07ea RS call point call point class as per GOST R 53325 2012 A class A one step activation B class B activation by performing several act...

Страница 4: ...l point are provided via the four wire communication line 2 wires RS 485 line Modbus RTU protocol 2 wires electrical power supply The call points must be connected to communication line in parallel wi...

Страница 5: ...r normal climatic conditions withstands a sinusoidal alternating voltage of 0 55 kV 50 Hz during one minute 2 17 Electrical resistance of insulation between the connected output conductors and the cal...

Страница 6: ...otection degree IP and the operating temperature range of cable glands should correspond to the operating conditions of the call point By agreement with the customer call points can be equipped with d...

Страница 7: ...al power supply The call points must be connected to communication line in parallel with strict observation of polarity Connection diagrams of the call point are shown in Annex B In order to configure...

Страница 8: ...s will cause the instrument to receive the Activated signal from the call point device it will display the corresponding message and will send back to the call point an acknowledgement of successful s...

Страница 9: ...explosion protection type explosion proof enclosure and explosion protection level 1 The protection degree IP and the operating temperature range of cable glands should correspond to the operating co...

Страница 10: ...cover and the body 6 12 The call point must be sealed after installation 7 SAFETY PROVISIONS 7 1 Compliance with the safety rules is mandatory for safe operation and use of the call points 7 2 Any wor...

Страница 11: ...n of the call point at the facility must follow the predesigned plan taking into consideration all the requirements hereof 8 5 Prior to installation of the call point at the site remove plugs from the...

Страница 12: ...ible 8 21 Check the completed installation by drawing attention to the correctness of the connections the presence of all fastening and locking elements and their correct installation 8 22 Close the c...

Страница 13: ...r and its address Customs Union conformity mark name or logo of certification authority and number of the certificate of compliance 9 3 The sequence of marking records is determined by the manufacture...

Страница 14: ...1 0 h 10 5 It is strictly prohibited to operate the call point with damaged explosion proof parts and any other defects 10 6 Opening of the call point cover and inspection are only allowed after all...

Страница 15: ...he fire device 11 3 In case of other more complicated failures their elimination can be carried out only at the manufacturer s factory Eridan JSC 11 4 In case of the call point s failure there are no...

Страница 16: ...al rules of cargo transportation 12 3 During transportation the requirements of the manipulation signs on the transportation packages must be strictly complied with During cargo handling and transport...

Страница 17: ...omer 14 CLAIM INFORMATION 14 1 Claims regarding quality of the call point are accepted upon submission of the call point this technical certificate and the report on hidden defects 14 2 The manufactur...

Страница 18: ...ed by the Certification Authority OS POZHTEST of FGBU VNIIPO of Emercom of Russia Certificate of compliance with the Technical Regulations of the Customs Union TR CU 020 2011 EAEU No RU RU 40 00693 20...

Страница 19: ...holes for sealing with the driving element the arrows on the call point nameplate must face vertically down as per the figure 7 lens 15 disk 23 24 washer 21 bolt 27 magnet 28 sealing ring 29 LED 30 b...

Страница 20: ...20 b Appearance of the call point IP535 07ea B...

Страница 21: ...3 removable element 4 body 6 cover the arrows on the device nameplate must face vertically down as per the figure 7 lens 8 protective element 15 disk 23 24 washer 21 bolt 27 magnet 28 sealing ring 29...

Страница 22: ...ble in cable gland KVBU 1 sheath wall maximum diameter for cable entry Dc 12 mm 2 cable insulation 3 sealing ring along the cable wrapping L 20 mm in uncompressed condition 4 washer 5 lock nut 6 union...

Страница 23: ...exceeding 2 5 mm is not allowed 2 insert the wire free from insulation into the inlet of the terminal 3 clamp the wire by releasing the terminal wrench or the screwdriver after that self disconnectin...

Страница 24: ...2 Terminal board of the call point IP535 07ea RS Table 5 The terminals designation for the call point IP535 07ea RS No of socket No of contact Designation of contact Description 1 1 6 Usup Feed throug...

Страница 25: ...of the contacts of the relay R2 Failure Terminal RTERM and additional RADD resistors are selected in accordance with FACP operation manual Install the jumper in terminals 3 7 of socket 2 of the call p...

Страница 26: ...f the call point Figure 5 Diagram of connection of the call point to fire alarm loop activated by closing The off position of the relay R1 Activated is configured as normally closed NC The call point...

Страница 27: ...ask and OR mask 0 17 reading and recording of various storage registers 0 2B 0 0E reading of device identifier processing of broadcast packets with a slave device address equal to 0 There is no respon...

Страница 28: ...ersion 0 65535 3 0x0008 8 0 03 UINT Serial number Lo 0 65535 0x0009 9 0 03 UINT Serial number Hi 0 65535 0x000A 10 0 03 UINT Device general status 1 6 1 booting 2 test 3 normal 4 acknowledgement reque...

Страница 29: ...t is activated 0 Installed 9 15 Reserve 14 Table 8 Configuration register register 50 0 0032 Bit No Designation Note 0 1 Activated signal is registered before reveiving a reset command status registra...

Отзывы: