6
1/1551-CRH 102 167 Uen Rev C 2007-04-19
The connectors on the Ericsson W20/21 are positioned as shown in the
following illustration:
Figure 2
Connectors’ panel
A description of each connector is provided in the table below (from left to
right):
Table 2
Connectors
Label Description
10-28 VDC
Power input for connecting the power supply adapter.
Reset
Button used to restore the Ericsson W20/21 configuration
to factory default settings. The following procedure resets
all configurable values back to factory default settings,
including the Ericsson W20/21 login user name and
password.
1. Disconnect the power cable from the W20/21 unit.
2. Press and hold the
Reset
button with the tip of a
pen and then reconnect the power cable. Keep the
button pressed for at least 20 seconds.
3. The Ericsson W20/21 restarts and comes online
with the factory default settings.
USB
USB connectors, for connecting Ericsson the W20/21 to a
USB printer.
LAN 1 - 4
Ethernet LAN connectors (RJ45), for connecting the
Ericsson W20/21 to client PCs or an Ethernet switch/hub.