Installing and Powering Up
Table 2.16 Ethernet CA 1 and 2 Interface Indicators
State Indication
Comment
Left Indicator (as viewed from the connector side):
Off
No active link
Green
Full duplex link present
Flashing for activity
Yellow
Half duplex link present
Flashing for activity
Right Indicator (as viewed from the connector side):
Off 10
Mbps
Green 100
Mbps
2.11.2
Static Parameters
2.11.2.1
Overview
lists all the static parameters associated with the Conditional Access
function. See
Chapter 3
and
Annex D,
for additional information relating to
Conditional Access.
Table 2.17 Static Parameters [CA]
Name Description
Value
CA1 IP Address
IP settings for CA port 1
10.1.101.6
CA 1 Subnet
IP settings for CA port 1
255.255.255.0
CA2 IP Address
IP settings for CA port 2
10.1.101.7
CA 2 Subnet
IP settings for CA port 2
255.255.255.0
CA Float Address
IP settings for the floating CA port
10.1.101.9
CA Float Subnet
IP settings for the floating CA port
255.255.255.0
ECMGs See
Table
emmg TCP Port
EMMG TCP port number
0
emmg UDP Port
EMMG UDP port number
0
pdg Port
PDG port number
0
EIS Port
EIS port number
0
ECMG connection timeout
Time before an inactive ECMG connection is
dropped
28
nominal CP duration
Crypto Period time (in deciseconds)
0
connection test interval
Interval for EMMG/ECMG/EIS/SCS connection
test messages (in seconds)
30
2/1553-FGC 101 1014 Uen B
2-25
Содержание MX8400
Страница 1: ...MX8400 Multiplexer Software Version 5 2 0 and later REFERENCE GUIDE 2 1553 FGC 101 1014 Uen B...
Страница 26: ...Installing and Powering Up 2 1553 FGC 101 1014 Uen B 2 4 BLANK...
Страница 94: ...Operating the Multiplexer using nCompass Control 2 1553 FGC 101 1014 Uen B 4 18 BLANK...
Страница 96: ...Preventive Maintenance and Fault finding 2 1553 FGC 101 1014 Uen B 5 2 BLANK...
Страница 146: ...Technical Specification 2 1553 FGC 101 1014 Uen B B 20 BLANK...
Страница 148: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 2 BLANK...
Страница 150: ...Static Parameters 2 1553 FGC 101 1014 Uen B C 4 Figure C 1 Typical Static Parameter Editor Display...
Страница 186: ...Redundancy Modes 2 1553 FGC 101 1014 Uen B E 2 BLANK...
Страница 192: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 2 BLANK...
Страница 196: ...IP Protocols 2 1553 FGC 101 1014 Uen B F 6 Figure F 3 Editing Stack Download Ports...
Страница 198: ...ProMPEG FEC Support for IP Streaming 2 1553 FGC 101 1014 Uen B G 2 BLANK...
Страница 204: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 2 BLANK...
Страница 212: ...Setting up the SFN Functionality 2 1553 FGC 101 1014 Uen B H 10 BLANK...
Страница 214: ...PSIG Support 2 1553 FGC 101 1014 Uen B I 2 BLANK...
Страница 220: ...BISS Support 2 1553 FGC 101 1014 Uen B J 2 BLANK...