![Erato Pony PS9 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/erato/pony-ps9/pony-ps9_user-manual_2421466037.webp)
Page.
37/55
5.4.
Stopping the operation of the stove.
Stopping the stove is done by holding button (4) for fey seconds. Then the
stove goes from working regime to a resting regime. That is realized by stopping
the fuel flow, the remaining fuel is burned and at the same time the stove stars to
cool. The flue gas fan stops after a predetermine time passes and the stove goes
to rest. In cases that work of the stove is not required for a long period of time is
recommender to be thoroughly cleaned.
ATTENTION: In case that the stove will not operate for a long period of time,
then the heat exchanger should be thoroughly cleaned from the deposited ash.
The deposited on the metal surfaces ash acts corrosively on the carbon steel
surfaces, which will lead to a decrease of the lifetime of the boiler’s main
modules – heat exchanger, as well as the burner. It is obligatory to perform
service procedures and preventive observations of the unit by trained service
personal only as well as thorough cleaning at the end of the heating season.
Completing these requirements will ensure long exploitation duration of the
stove and its high efficiency and reliability.
5.5.
Cleaning the stove
In order to maintain high efficiency and reliability of the stove the regular
cleaning of the accumulated ahs residue is obligatory. The ash residue is a
function of the duality of the pellets.
Before cleaning the stove needs to be stopped, cooled and disconnected
from the power grid.
The cleaning of the ash residue is done manually, by a brush or a vacuum-
cleaner designed for that purpose. It is recommended after cleaning the ash to be
thrown to a designated for that purpose place;