EXPLANATION: The surface temperature of the marked zone 1can exceeds
80
o
C, the temperature of the glass (marked as Zone 2) of the burning chamber
can rich 280-300
o
C;
•
Placing the stove according connection to the power supply: Place the
appliance so a free connection to a power outlet can be easily made
(230V/50Hz). It is prohibited the stove to be installed in room with power
installation mounted on the floor.
•
Before connecting the stove to the chimney you must check if the chimney is
cleaned, with the required debit and if it ensures the required draught. Make
the chimney air tide to prevent the possibility of flue gases escaping. The use
of heat resisting silicon is recommended. It is prohibited the use of cement or
cement based materials for packing the chimney. In case of using an existing
chimney it needs to be thoroughly checked for functionality and safe work,
because some untied places can cause flue gases to escape to living area and
to harm the health of the inhabitances. In case of the existing chimney not
being air tide you need to fix so it will be safe to use.
ATTENTION: It is prohibited the direct exhaust of flue gases thru a wall.
The use of chimney is obligatory. The chimney exhausts the flue gases to a
safe height away from the inhabited zone.
In cases of using external chimney (Chimney which is not a part of the
building and it is mounted independently to a side wall of the building.), you
must check the following:
•
You must use pre insolated chimneys (“Double pipe”), mounted to the
side of the building;
•
In the base of the chimney you must install an opening for cleaning
and maintenance;
•
The chimney must be well placed and mounted protected from storms,
wind and rain. Also it needs to meet the minimum distance from the
highest point of the roof.