Maintenance 3. Covers
LS Rev.10
77
3.4 Connector Sub Plate
CAUTION
■
Do not remove the connector sub plate forcibly. Removing the connector sub
plate forcibly may result in damage to the cables, disconnection, and/or contact
failure. Damaged cables, disconnection, or contact failure is extremely
hazardous and may result in electric shock and/or improper function of the robot
system.
■
When installing the connector sub plate, be careful not to allow the cables to
interfere with the plate mounting and do not bend these cables forcibly to push
them into the cover.
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure. Damaged cables, disconnection, or contact failure is
extremely hazardous and may result in electric shock and/or improper function of
the robot system.
When routing the cables, observe the cable locations after removing the
connector sub plate. Be sure to place the cables back to their original locations.
Unscrew the Connector Sub Plate mounting
bolts and remove the plate.
The fittings position and size of the Connector
Plate are different for LS6 and LS3.
The screws’ position and size are common.
The figure is LS3.
4-M4
×
5
Connector
Sub Plate
3.5 User Plate
User Plate
Removal
(1) Remove the Arm Top Cover.
Refer to
Maintenance: 3.1 Arm Top Cover
.
(2) Unscrew the User Plate mounting bolts and
remove the plate.
2-M4
×
10
User Plate
Installation
(1) Put the User Plate to the arm and secure
using the mounting bolts.
(2) Mount the Arm Top Cover.
Refer to
Maintenance: 3.1 Arm Top Cover
.
NOTE
Содержание LS series
Страница 1: ...Rev 10 EM16XR3299F SCARA ROBOT LS series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS series Rev 10 ...
Страница 10: ...viii LS Rev 10 ...
Страница 14: ...TABLE OF CONTENTS xii LS Rev 10 ...
Страница 16: ......
Страница 77: ...Maintenance This volume contains maintenance procedures with safety precautions for LS series Manipulators ...
Страница 78: ...64 ...