Maintenance 7. Arm #3
LS Rev.10
113
(5) Remove the Control board.
For details, refer to
Maintenance: 11.3 Replacing
the Control Board
.
Control Board
Palgen
(6) Remove one screw that mounts the special power
supply on the User Plate.
(7) Cut off the wire tie binding the cables.
Cut off the wire tie binding the Joint #3 brake cable to the Arm #2 column.
At this point, do not cut off a wire tie (in the duct fittings outlet) that binds the cables to
the User Plate.
(8) Disconnect the following connectors.
Connectors X31, X32, X231 (Hold the claw to remove.)
(9) Remove the User Plate.
For details, refer to
Maintenance: 3.5 User Plate
.
(10) Remove the screws for the Joint #3 motor unit
and pull out the Joint #3 motor unit.
3-M4×15
+ Washer
Joint #3
Motor Unit
(11) Remove the screws for the spline plate.
Holding the spline plate upward, pull out the Z
belt.
Z Belt
Spline Plate
3-M4×12