Maintenance 11. Lithium Battery and Boards
LS Rev.10
149
11.2 Replacing the Resolver Board
After battery board and parts have been replaced (motors, reduction gear units, brakes,
timing belts, ball screw spline unit, etc.), the manipulator cannot operate properly because
a mismatch exists between the origin stored in each motor and its corresponding origin
stored in the controller.
After replacing the parts, it is necessary to match these origins.
The process of aligning the two origins is called “Calibration”.
Refer to
Maintenance: 13. Calibration
to execute the calibration.
Resolver Board
Removal
(1) Turn OFF the controller.
(2) Remove the Connector Plate.
For details, refer to
Maintenance: 3.3 Connector Plate
.
(3) Disconnect three batteries connectors and the M/C
signal connector.
(3)
(4)
(3)
(4)
(4) Remove the screws (flat head screw
×
4) on the side
face of the Base.
Slowly pull out the resolver board and heat-transfer
sheet from the Base.
The signal connector is connected. Do not pull out
forcibly.
(5) Disconnect the connectors X10 and X20 from the resolver board.