Maintenance 11. Lithium Battery and Boards
148
LS Rev.10
11.1 Replacing the Battery Unit (Lithium Battery)
Battery unit
(lithium battery)
Removal
(1) Turn OFF the controller.
(2) Remove the Connector Plate.
For details, refer to
Maintenance: 3.3 Connector Plate
.
(3) Take out the battery plate from the Base.
Battery plate mounting screw: 1 - M3
×
5
Be careful not to disconnect the battery connector.
If you disconnect all the current batteries before connecting the new battery, the robot
will lose the home position data and the calibration must be executed again. The
battery units are exchanged according to the following procedures.
Battery Plate
Battery
Mounting Screw
Cable Support
(4) Cut off the wire tie binding the lithium batteries to the battery plate.
(5) Bind new batteries to the battery plate with a new wire tie.
(6) Mount the battery plate to the cable support.
Battery plate mounting screw: 1 - M3
×
5
(7) Disconnect one connector of the old three batteries and connect a new one.
(8) Disconnect the other old batteries connector and connect new ones.
(9) Mount the Connector Plate.
For details, refer to
Maintenance: 3.3 Connector Plate
.
(10) Turn ON the controller.
(11) Check if the manipulator moves to points correctly in correct orientation.
To do so, select some points already registered and move the manipulator to the
points.
(12) If the manipulator does not move to the points correctly, execute the calibration of all
joints and axes.
For details, refer to
Maintenance: 13. Calibration
.
NOTE
Содержание LS series
Страница 1: ...Rev 10 EM16XR3299F SCARA ROBOT LS series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS series Rev 10 ...
Страница 10: ...viii LS Rev 10 ...
Страница 14: ...TABLE OF CONTENTS xii LS Rev 10 ...
Страница 16: ......
Страница 77: ...Maintenance This volume contains maintenance procedures with safety precautions for LS series Manipulators ...
Страница 78: ...64 ...