1.4.2 Controller Firmware Ver. 7.0.2.4 or later
If the Manipulator moves abnormally during operation, immediately press the Emergency
Stop switch. Pressing the Emergency Stop switch immediately changes the manipulator
to deceleration motion and stops it at the maximum deceleration speed.
However, avoid pressing the Emergency Stop switch unnecessarily while the Manipulator
is running normally. Pressing the Emergency Stop switch locks the brake and it may
cause wear on the friction plate of the brake, resulting in the short life of the brake.
Normal brake life cycle: About 2 years (when the brakes are used 100 times/day)
To place the system in emergency mode during normal operation, press the Emergency
Stop switch when the Manipulator is not moving.
Refer to the Controller manual for instructions on how to wire the Emergency Stop switch
circuit.
Do not turn OFF the Controller while the Manipulator is operating.
If you attempt to stop the Manipulator in emergency situations such as “Safeguard Open”,
make sure to stop the Manipulator using the Emergency Stop switch of the Controller.
If the Manipulator is stopped by turning OFF the Controller while it is operating,
following problems may occur.
Reduction of the life and damage of the reduction gear unit
Position gap at the joints
In addition, if the Controller was forced to be turned OFF by blackouts and the like while
the Manipulator is operating, make sure to check the following points after power
restoration.
Whether or not the reduction gear is damaged
Whether or not the joints are in their proper positions
If there is a position gap, perform calibration by referring to the
Maintenance 13.
Calibration
in this manual.
Before using the Emergency Stop switch, be aware of the followings.
-
The Emergency Stop (E-STOP) switch should be used to stop the Manipulator only
in case of emergencies.
-
To stop the Manipulator operating the program except in emergency, use Pause (halt)
or STOP (program stop) commands
Pause and STOP commands do not turn OFF the motors. Therefore, the brake does
not function.
-
For the Safeguard system, do not use the circuit for E-STOP.
For details of the Safeguard system, refer to the following manuals.
EPSON RC+ User’s Guide
2. Safety - Installation and Design Precautions - Safeguard System
Safety and Installation
2.6 Connection to EMERGENCY Connector
Содержание LS series
Страница 1: ...Rev 10 EM16XR3299F SCARA ROBOT LS series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS series Rev 10 ...
Страница 10: ...viii LS Rev 10 ...
Страница 14: ...TABLE OF CONTENTS xii LS Rev 10 ...
Страница 16: ......
Страница 77: ...Maintenance This volume contains maintenance procedures with safety precautions for LS series Manipulators ...
Страница 78: ...64 ...