Maintenance 8. Arm #4
LS Rev.10
137
8.4 Checking the Timing Belt Tension (U1, U2 Belts)
Name
Quantity
Note
Tool
Sonic tension meter
1
For details of usage and measurement methods of the tension
meter, refer to the instruction manual of the tension meter.
Joint #4
Belt tension
check
(1) Enter appropriate setting values to the sonic tension meter.
Model
Belt
Unit mass M
[g/ (1 mm width ×1 m length)]
Width W
[mm]
Span S
[mm]
LS3
U1 belt
1.3
10
45
U2 belt
1.3
16
92
LS6 (a)
U1 belt
1.3
10
54
U2 belt
1.3
15
170
LS6 (b)
U1 belt
2.0
10
54
U2 belt
2.0
15
170
(2) Strum the U2 belt and measure tension.
Measurement failure may occur if the
microphone touches the belt during
measurement.
(3) LS6 only:
Remove the rubber plug from the hole
on the Arm #2.
(4) Strum the U1 belt and measure tension.
For LS6, insert the microphone of the
tension meter to the hole on the Arm to
measure tension.
Measurement failure may occur if the
microphone touches the belt during
measurement.