Maintenance 12. Replacing the Lithium Battery
186
E2C Rev.6
Installation
Be sure to use the specified “battery unit for signal relay board (Code:
R13ZA00600300)”.
Observe polarity (positive/negative) when connecting the lithium battery.
(1) Connect the X60 connector to the new
lithium battery.
Lithium battery
(2) Secure the lithium battery to the battery
box.
Wire tie
Lithium battery
(3) Mount the battery box on the base
connector box.
2-M3×6
sems screw
Battery box
(4) Connect the connectors and tubes to the base connector box (outside).
(5) Turn ON the Controller.
(6) Check if the Manipulator moves to points (pose) correctly.
To do so, select 2 points (pose) or more from the registered points (pose) and move
the Manipulator to the points (pose).
(7) If the Manipulator does not move to the points (pose) correctly, perform the
calibration of all joints and axes.
For details on the calibration method, refer to
Maintenance: 14. Calibration
.
)
NOTE