High Temperature Assembly
To prevent you from becoming injured or burned, do the following: Before working
with a high temperature assembly (e.g., FUSER ASSY), be sure to turn off the power,
unplug the power cord and wait until it cools down adequately.
Ozone
Because of the printing principle of laser printers, this machine emits a very small
amount of ozone in the process of printing. (The exhaust air may smell of ozone.) This
printer generates only a very small amount of ozone that never exceeds the safety
permissible value (0.1 ppm / 0.2 mg/m
3
) in the normal work environment. Avoid
operating the printer under any of the following conditions:
Any ambient conditions other than specified for use of this printer
Use of two or more laser printers in a small room
Use in a place where sufficient ventilation is not available
Especially, continuous operation for an extended period of time under any of the
above-mentioned conditions
C A U T I O N
The high temperature assembly is very hot immediately after any
printer operation. Wait at least 40 minutes, until the printer cools
down adequately.
JG0105EA
FUSER ASSY
Warning Label
Содержание AcuLaser M4000N
Страница 1: ...EPSON EPL N3000 AcuLaserM4000N A4 Monochrome Laser Printer SERVICE MANUAL SEPG03004 Confidential ...
Страница 19: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 33: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 63: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 160: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 396: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 404: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 408: ...Confidential C H A P T E R 7 APPENDIX ...